CHAPTER 4
Performing Advanced Functions
R
ETURNS
R
EMARKS
R
EMOTE
E
XAMPLE
C
OMMAND
Following notification types can be returned when issuing the
RNTTL command:
Value
00
01
10
11
The return result depends on the control byte (see table). However,
whatever the return result is, it includes the control byte.
The general behavior is that an ANLG command issued on a cer-
tain input channel will override any previous ANLG commands
affecting that channel.
The A723 device cannot issue ANLG commands remotely, but can
execute them.
For RSM
ANLG 0
9999 ANLG 0 5 5 5 5 5 5 5 5 4 4 5 5 0
#
For SSMAA (on channel 4)
ANLG 68
9999 ANLG 68 0
#
For DAN (on channel 0)
ANLG 160
9999 ANLG 160 0
#
For RNTTL (on channel 2)
ANLG 178
9999 ANLG 178 340 3900 0
#
For ENOPTR (on channel 10)
ANLG 202 1000
9999 ANLG 202 0
#
PORT
Notification Type
Notify On Positive Threshold.
Notify On Negative Threshold.
Notify if Out of Limits.
Notify if Inside the Limits.