34
CHAPTER 4
Performing Advanced Functions
C
OMMAND
APPLIES TO
D
ESCRIPTION
P
ARAMETERS
R
ETURNS
REMARKS
REMOTE
E
XAMPLE
C
OMMAND
APPLIES TO
D
ESCRIPTION
P
ARAMETERS
PMP
193 PMP 65 72 0
#
CM
A723
Sets/returns the A720 compatibility mode.
0 means A723 native mode while 1 switches the unit in A720 com-
patible mode. In this mode, although the device presents itself as
an A723 (when issuing the INFO command), it will return the frame
type 38 when asked for DATA (see also "DATA" on page 36). This
mode is useful when the A723 device is used with the A720B base
station or with an addVANTAGE 3.35 software (addVANTAGE 3.4
and later recognizes an A723 in its native mode).
There is also an additional compatibility mode (CM 2) that forces
the A723 to respond with an A720 compatible answer to the INFO
command. This mode is not recommended for normal use.
By default the A723 devices are delivered in native mode (CM is 0).
The current mode.
GET/SET.
No.
CM 1
193 cm 0
#
CM
193 CM 1 0
#
SST
A723
Sets/returns Sensor Sampling Time. This is the delay allowed for
the sensors to settle after applying them power and until they are
sampled.
The settling time in seconds.