R
EMARKS
REMOTE
E
XAMPLE
C
OMMAND
A
PPLIES TO
D
ESCRIPTION
P
ARAMETERS
— 4 for A733
— 5 for A723
— 6 for A440
slot and samples are the actual values programmed by
•
means of the SLOT command
po (A723 only) is the relative output power
•
err_level is the error value; 0 means no error
•
GET only.
Yes, GET only. The A720B and A723 can issue the command both
remotely and locally, while the A720 can issue the command only
locally.
INFO
193 INFO 255 0 18/4/1999 21:5:11 1.3 0 0 0 91 72
40 1:46 58 65 72 3 900 0 0
#
ANLG
A723
Sets/returns various parameters of the analog subsystem (e. g. the
sampling/averaging method used for individual data aquisition
channels).
A control byte specifying the command and the analog input chan-
nel number the command is acting on:
Command Code
Figure 13. The ANLG Control Byte Layout.
Some commands may also require one or two additional 16 bit
parameters representing threshold values.
•
The Channel Number selects the analog channel that will be
affected by the command. For the A723 device, only 0000 to
0101 are accepted (only 6 analog channels are available).
CHAPTER 4
Using terminal commands
Channel Number
43