Page 2
All programming of the V21 is done in the service mode as indicated in the following steps below. The main service modes are indicated in white text and the sub-modes are indicated in black text. Example: Time/Date Setting Mode Year Setting...
Page 3
THREE-BUTTON PROGRAMMING All programming of the V21 control board is done in the service mode. To enter the service mode open the vendor door, find the service mode button located on the control board, then press and release the service mode button. To scroll though all the service modes, use selection button one.
Page 4
SET-UP AND CODE DESCRIPTION Error Display Mode If selection button two is pressed at the “ ” prompt, the controller will enter the Error Display Mode. If no errors have occurred, the display will show “ ”. If an error has been detected since the last error reset, the display will show the first error summary code that has occurred.
Page 5
SET-UP AND CODE DESCRIPTION (CONTINUED) Jogging the Column Pressing selection button two at the “ ” mode, will enter into the Jog test mode. Upon entry into the Jog test mode the display will show the first summary test, “ ”...
Page 6
SET-UP AND CODE DESCRIPTION (CONTINUED) MIS Data – Sales Mode If selection button two is pressed at the “ ” prompt, the display will show the non-resettable historical amount of units sold by the machine. If selection button one is pressed, the display will show “...
Page 7
SET-UP AND CODE DESCRIPTION (CONTINUED) Depth Setting Mode The purpose of this mode is to enable the controller to set the vending depth for each column. If selection button two is pressed at the “ ” prompt, the display will indicate “ ”.
Page 8
SET-UP AND CODE DESCRIPTION (CONTINUED) Space-to-Sales Setting Mode If selection button two is pressed at the “ ” prompt, the controller will enter the Space- to-Sales option. Upon entry into this setting the display will show the current option setting. Pressing selection button one will scroll through the various space to sales options as listed below.
Page 9
SET-UP AND CODE DESCRIPTION (CONTINUED) Closed Door Data Retrieval Mode If selection button two is pressed at the “ ” prompt, the controller will enter the Closed Door Data Retrieval Mode by displaying “ ” where “ ” is the password. Pressing selection button number one while the digits are flashing will change the current password.
Page 10
SET-UP AND CODE DESCRIPTION (CONTINUED) Lighting Control Mode If selection button two is pressed at the “ ” prompt, the controller will enter the Lighting Control Mode which allows you to have the lights turned off and on during specific time periods to conserve energy.
Page 12
SET-UP AND CODE DESCRIPTION (CONTINUED) REFRIGERATION CONTROL SETTINGS Refrigeration control enabled (1)/disabled (0) Start Time – Time temperature rises 18°F/10°C Days associated with start time Hour associated with start time End Time – Time temperature returns Days associated with end time Hour associated with end time Start time –...
Page 13
SET-UP AND CODE DESCRIPTION (CONTINUED) BLOCK SELECTION OPTIONS Controls blocking option Set selection buttons – (y) assigned/(n) not assigned Set time for machine to turn off Set days for blocking to start Set hours for blocking to start Set time for machine to turn back on Set days for blocking to stop Set hours for blocking to stop Discount Setting Mode...
Page 14
SET-UP AND CODE DESCRIPTION (CONTINUED) Over-Ride Mode (Units equipped with optional key switch) This feature is used to allow you to manually over-ride (via a key switch) pricing, blocking, low energy operation and discounting. If selection button two is pressed at the prompt, the controller will enter the Over-Ride Mode.
Page 15
SET-UP AND CODE DESCRIPTION (CONTINUED) Over-Ride Lighting If selection button two is pressed at the “ ” prompt, the controller will enter the Lighting Over-Ride Option. Upon entry into this program the display will show the current setting for enable and “ ”...
Page 17
12.1 WIRING DIAGRAM (CONTINUED) VEND MOTORS (24 VDC) MOTOR # 10 MOTOR # 9 MOTOR # 8 MOTOR # 7 MOTOR # 6 MOTOR # 5 MOTOR # 4 MOTOR # 3 MOTOR # 2 MOTOR # 1 (WHEN USED) (WHEN USED) TYPICAL MOTOR CIRCUIT WITH SOLDOUT OPTION...
Page 18
NOTES 1. If the outer door is left open for over an hour, the lights, and compressor will become active. In order to over-ride this option, press the door switch one time. 06/2005...