4. CABLE STRIPPING DIMENSIONS FOR PRIMARY POWER CONTACTS
Connector
Series
SBE320 / SBX350
SBE160 / SBX175
5. RECOMMENDED SOLDERING TECHNIQUES
(Use rosin flux solder only). Wrap cable strands, melt solder into well; heat and insert stripped cable. Continue
heating well until solder flows into wire being careful not to over flow onto contact surfaces. DO NOT SOLDER DIP
CONTACTS when contacts are soldered to unsupported lead. Underwriters' Laboratories, Inc. requires use of cable
clamps, listed in table below.
Connector
Ampere Rating
SBE320 / SBX350
SBE160 / SBX175
6. CABLE / CONTACT & HOUSING ASSEMBLY
Observing polarity of markings, push each contact into rear of housing until notched side snaps
over spring, tug on cable to make sure contact is locked into place.
DISASSEMBLING CONNECTORS (see illustration)
Switch off power first. Remove contact by inserting extraction tool (cat. no. SBE160 / SBX175 - 969P1, SBE320 /
SBX350 - 970P1) as shown below (steps 1, 2, & 3).
CAUTION: Replace contacts individually on battery leads to reduce potential danger of shorting.
1. Insert extraction tool as shown between contact and housing to point A.
Extraction Tool
2. Press down to release contact from spring.
3. Pull cable to remove contact.
2
Extraction Tool
SBE
/ SBX
®
Strip "X" To
Inches
mm
1 3/8
35
1 1/8
29
For Two Single
Conductor Cables
911G2
945G2
Point A
Assembly Instructions
®
X
3

Advertisement

loading

This manual is also suitable for:

App sbx seriesApp sbe160 seriesApp sbe320 seriesApp sbx175 seriesApp sbx350 series