14
TECHNICAL CHARACTERISTICS
Power supply
90 ... 265 VAC 50, 60 Hz
18 ... 36 VDC
Power consumption: ≤ 5 VA
Resistance input
Range:
Resolution:
Current input
Range:
Resolution:
Analog output
4-20 mA. Active or passive. Galvanically isolated from the power supply.
Relay outputs
2 relays with potential free contacts.
Contact characteristics:
Maximum voltage
Maximum current:
Level indication
Nº of digits:
Digit size:
** When the available digits are full and the integers overflow a decimal is automatically
lost.
Ambient temperature range:
-20ºC ... +60 ºC
Housing
Material:
Box:
Front frame: Lexan 920 black
Ingress protection:
Back side:
Front side:
Silicone sleeves for the front side are available. They provide an IP65 ingress protection.
Conforms to Low voltage Directive 2006/95/CE
Conforms to Electromagnetic compatibility Directive 2004/108/CE
Conforms to Waste Electrical and Electronic Equipment Directive 2002/96/CE
(1)
Noryl and Lexan are trademarks of Saudi Basic Industries Corporation (SABIC).
0 ... 6500 Ω
2 Ω
4 ... 20 mA
7 μA
: 220 VDC, 250 VAC
: 3 A
Noryl SE1, GFN2, 701 black
IP30
IP50
5 (up to 2 decimals configurable)**
11 mm
(1)
(1)
29