Troubleshooting - Bossard KDG 1000 Series Operating Instructions Manual

Dosing unit
Table of Contents

Advertisement

FAULT
No display
No change in value in the pressure
display
No dosing
Too little or too much product
Product drips

Troubleshooting

CAUSE
• No supply voltage
• Defective power supply (22)
• Power switch (1) in OFF position
• Defective power switch (1)
• Defective display
• No compressed air
• Defective pressure regulator (2)
• Defective control unit
• Foot switch (18) not connected
• No compressed air
• Dosing pressure not
set correctly
• Connection hose (21) between device
and cartridge not plugged in
• Dosing nozzle (27) clogged
• Defective control unit
• Dosing pressure not
set correctly
• Wrong dosing nozzle mounted
• Vacuum regulator (3) set too low
• Vent (14) clogged
18
REMEDY
• Check supply voltage
• Power switch (1) in ON position
• Replace power switch (1) (service center)
• Replace power supply (22)
• Replace display (service center)
• Check compressed air supply
• Service center / supplier
• Service center / supplier
• Connect foot switch (18)
• Check compressed air supply
• Correct dosing pressure setting
• Insert connection hose
• Replace dosing nozzle (27)
• Service center / supplier
• Correct dosing pressure setting
(see page 15)
• Switch dosing nozzle
• Turn vacuum regulator (3) counterclock-
wise until the dripping stops
(see page 15)
• Check ventilation