Reactor Error Code Trouble Shooting Guide
E29: Brush Wear (E-Series Only)
Causes:
1) Normal brush wear, causing the brush sensor to come in contact with the motor
commutator.
o Replace the brushes p/n-234037.
2) The spade plug inside the motor housing is twisted and making contact with the
commutator side of the brush sensor assembly, causing a false alarm.
o Follow the orange wire coming from J7 (E-20/E-XP1), or J6 (E-30/E-XP2), up to
the spade connector on the motor. Using a flashlight to see check and make sure
the spade plug assembly is not making contact with the metal housing of the brush
assembly.
3) The yellow brush sensor wire coming out of the brush is routed in-line with the
commutator wiring (thick red wire), causing a false alarm.
o Reroute the yellow wire coming out of the brush, away from the commutator
wiring.
4) The motor control board has failed.
o To check:
 Remove the plug in J7 (E-20/E-XP1), or J6 (E-30/E-XP2). (This will
 To remove the E27 alarm, use a jumper wire on the motor control board,
 The E27 as well as the E29 alarm should be gone. If the E27 alarm is not
 If the jumper is installed correctly and the E29 alarm is still there. This
Rev 2.6 (02/2014)
cause an E27 alarm).
across the two pins that the two yellow wires plugged into. Then turn the
unit on.
gone double-check your jumper.
would indicate the motor control board is bad. Replace the motor control
board.