Reactor Error Code Trouble Shooting Guide
E09: Heater and Display Communication Malfunction
(Return to Table Of Contents)
Cause:
Communications between the heater control module and the display is not functioning.
1)
When communication is lost, the display will show E09.
Check all wiring between the display and the heater control module.
o Pay close attention to the wire crimping on plug J5/DISPLAY C of temperature
control module.
o Swap J5 of temp control side with J13 on motor control side to see if problem is in
the harness/control or display.
If E09 remains on the same display, replace the Display
If E09 moves to other display then reverse the J13 connections on the display
boards to determine if cable or temperature control module is the cause.
Rev 2.6 (02/2014)