Graco Reactor E-XP1 Troubleshooting Manual page 18

Error code trouble shooting
Hide thumbs Also See for Reactor E-XP1:

Advertisement

Reactor Error Code Trouble Shooting Guide
 Check the FTS with an ohmmeter.
o Locate the FTS.
o With the main power off, unplug the FTS and measure the pins on the FTS.
If the FTS fails any test, replace.
0A (zero amps) on the Hose Zone Display.
o If the FTS is disconnected or the display shows E04, turn the main disconnect off, then
on to clear the alarm, and default the machine into manual current hose heat mode. 0A
(zero amps) will show in the actual display with the hose zone off.
o When in the target mode of the hose heat zone, amperage can be adjusted from 20A to
45A with the up and down arrow keys.
o To prevent hose overheating, install a thermometer close to the gun end, within the
operators view. Insert thermometer through foam insulation cover of the "A" component
hose so stem is next to the inner tube. Thermometer reading will be approximately 20°F
less than the actual fluid temperature. It the thermometer reading exceeds 160°F (71°C),
reduce the current with the down arrow key.
o Thermometer reading should never exceed 160°F (71°C). Never leave the
machine unattended while in a manual current control mode.
Rev 2.6 (02/2014)
 Pins 1 to 2 10 Ohms
 Pins 1 to 3 = Infinity "OL" Open Loop
 Pin 3 to FTS ground screw = 0 ohms
 Pin 1 to FTS component "A" (ISO) fitting = Infinity
Page 18