Specification - ABB AquaMaster Explorer Installation Manual

Electronic commercial water meter powered by external battery pack
Hide thumbs Also See for AquaMaster Explorer:
Table of Contents

Advertisement

SPECIFICATION

Specification
Transmitter
Mounting
Directly on sensor
or
Remote up to 200m (650 ft)
Housing
IP68 (NEMA 6P)
Stainless steel housing in a Thermoplastic outer cover with
window, encapsulated with polyurethane-based resin.
Electrical connections
IP68 plug & socket
Sensor cable
ABB cable supplied as standard
SWA cable available (via adaptor box) on application
External battery pack
IP68 (NEMA 6P)
Battery life @ 0 to 50°C (32 to 122°F) typically 5 years
Extended life is possible to give, say, 6 years with a small
degradation in response time and slightly increased measurement
uncertainty (contact ABB for details).
Battery life is shorter with GSM, depending on how frequently it is
used and for what period. For example, used once per day for
SMS automated reporting of data logged at 15 minute intervals,
the life of a battery pack would be typically reduced to
approximately 4 years.
Pulse and alarm outputs
Three bidirectional solid state switches with common isolation
±35V DC 50mA
Output 1 Forward only, or forward plus reverse pulses
Output 2 Reverse pulses, or direction indicator
Output 3 Alarm indicates any problem with measurement or with
power
Pulse output 50Hz maximum, 50% nominal duty cycle
Serial data communications
Local Port RS232 compatible via ABB lead (Option)
Temperature Ranges
24
Process
Ambient
70 C (158 F)
–10 C (14 F)
Encoder Interface (non-logging versions only)
Function
Remote reading of totalizer and serial no.
Protocol
ABB encoder
Connections
2-wire for inductive pads (max. cable length 80m)
3-wire for AMR
Compatible readers
Severn Trent Services Smart reader
ABB or Elster SR100 and SR50
Logicon Versaprobe
Itron ERT
Compatible inductive pads
Starpad
ABB
Telemetry applications using remote serial data
communications
Internal GSM modem Dual Band GSM; fully programmable
schedule for battery operation and Automated Meter Reading
Pressure System – External Transducer
Pressure range
16bar g or 16 bar Abs
Connection
Standard quick-fit male probe connector via an adapter cable
Operating temperature range
–20 (ambient) to 70°C (–4 to 158°F)
Caution. Protect the sample and transducer from
freezing.
Accuracy (typical)
±0.4% of range
Thermal error band (typically 100°C [212°F])
±1.5% span
Cable length
5 or 10m (16 or 33 ft)
Storage
70 C (158 F)
60 C (140 F)
–20 C (–4 F)
–30 C (–22 F)