Air hAndling unit
KOMFORT EC S200
KOMFORT EC S200-E
KOMFORT EC SB200
KOMFORT EC SB200-E
KOMFORT EC S250
KOMFORT EC S250-E
KOMFORT EC SB250
KOMFORT EC SB250-E
Air handling unit
EN
USER'S MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KOMFORT EC S200 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BLAUBERG Ventilatoren KOMFORT EC S200 Series

  • Page 1 Air hAndling unit KOMFORT EC S200 KOMFORT EC S200-E KOMFORT EC SB200 KOMFORT EC SB200-E KOMFORT EC S250 KOMFORT EC S250-E KOMFORT EC SB250 KOMFORT EC SB250-E Air handling unit USER'S MANUAL...
  • Page 2: Table Of Contents

    KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de CONTENTS Safety requirements ..................................3 Purpose ........................................ 5 Delivery set ......................................5 Designation key ....................................5 Technical data ....................................6 Design and operating principle ............................7 Mounting and set-up .................................. 10 Connection to power mains ..............................13 Technical maintenance ................................
  • Page 3: Safety Requirements

    KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de SAFETY REQUIREMENTS • Please read the user’s manual carefully prior to installing and operating the unit. • All user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical, and technical norms and standards must be observed when installing and operating the unit.
  • Page 4 KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de • Do not allow children to operate the unit. • The unit is allowed to be used by children aged from 8 years oldand above and persons with reduced physical, sensory, • Disconnect the unit from or mental capabilities or no power mains prior to any experience and knowledge...
  • Page 5: Purpose

    KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de PURPOSE The unit is designed to ensure continuous mechanical air exchange in houses, offices, hotels, cafes, conference halls, and other utility and public spaces as well as to recover the heat energy contained in the air extracted from the premises to warm up the filtered stream of intake air.
  • Page 6: Technical Data

    KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de TECHNICAL DATA The unit is designed for indoor application with the ambient temperature ranging from +1 °C up to +40 °C and relative humidity up to 80 %. In order to prevent condensation on the internal walls of the units, it is necessary that the surface temperature of the casing is 2-3 °C higher than the dew point temperature of the transported air.
  • Page 7: Design And Operating Principle

    KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de DESIGN AND OPERATING PRINCIPLE KOMFORT EC S(B)200(-E) 1 – bypass damper (KOMFORT EC SB200/250(-E)) 2 – supply fan 3 – FS1 or FS2 humidity sensor (installed at the request of the customer) 4 – control unit 5 –...
  • Page 8 KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de Compatibility table of optional equipment and unit models KOMFORT EC S200 S14 KOMFORT EC SB200 S14 — — — KOMFORT EC S200-E S14 KOMFORT EC SB200-E S14 — — — KOMFORT EC S250 S19 — KOMFORT EC S250 S14 —...
  • Page 9 KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de AIR FLOW DIRECTION The air flow direction depending on the operation mode of the KOMFORT EC S(B)200(-E) unit is shown below. Freeze protection Summer Cooling mode Heat Recovery mode Supply fan is off Bypass duct is opened Bypass duct is opened KOMFORT EC S(B)200(-E) KOMFORT EC S(B)200(-E)
  • Page 10: Mounting And Set-Up

    KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de MOUNTING AND SET-UP READ THE USER'S MANUAL BEFORE INSTALLING THE UNIT. HUMIDITY SENSOR MOUNTING IN THE EXTRACT AIR DUCT CAUTION! The humidity sensor must be installed in the air duct prior to the unit mounting. FS1 humidity sensor mounting sequence: •...
  • Page 11 KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de SERVICE SIDE CHANGE • Unscrew the front panel on the service side and the back panel. • Remove the panels and change their positions. Attach the panels with screws to the casing. The delivery set includes a label indicating the filter type and the air flow direction. Stick it on a removable plate (only for the KOMFORT EC S(B)250(-E) units).
  • Page 12 KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de UNIT INSTALLATION To get the best performance of the unit and to minimize turbulence-induced air pressure losses, connect the straight air duct section to the spigots on both sides of the unit while installing. Minimum straight air duct length: •...
  • Page 13: Connection To Power Mains

    KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de CONNECTION TO POWER MAINS POWER OFF THE POWER SUPPLY PRIOR TO ANY OPERATIONS WITH THE UNIT. THE UNIT MUST BE CONNECTED TO POWER SUPPLY BY A QUALIFIED ELECTRICIAN. THE RATED ELECTRICAL PARAMETERS OF THE UNIT ARE GIVEN ON THE MANUFACTURER’S LABEL.
  • Page 14 KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de EXTERNAL WIRING DIAGRAM FOR THE KOMFORT EC S(B)200(-E) S14 UNIT PK re alarm panel (remove the jumper while P1 control Electric actuators connecting the contact) panel of the external air dampers humidity sensor - Tx Rx + External device supply exhaust...
  • Page 15 KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de EXTERNAL WIRING DIAGRAM FOR THE KOMFORT EC S(B)250(-E) S14 UNIT +U 0-10V SM-LSM-N 1 2 3 4 5 6 7 8 9 10 11 12 13 6 7 8 +U 0-10V GND SM1* SM2* FS1* CO2* PK1* —...
  • Page 16 KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de EXTERNAL WIRING DIAGRAM FOR THE KOMFORT EC S(B)250(-E) S19 UNIT +12V L1 L1 no c +12V *SM2 *SM1 Р1 *PK1 Designation Name Model Wire *CCU DX cooler 2x0.75 mm *SМ1 Supply air damper actuator LF 230 2x0.75 mm *SМ2 Extract air damper actuator...
  • Page 17 KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de EXTERNAL WIRING DIAGRAM FOR THE KOMFORT EC S(B)250(-E) S21 UNIT NO C +24V +24V 0-10V 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 0-10V +24V +24V SM1* SM2* PK1* Boost* CO2* Designation...
  • Page 18: Technical Maintenance

    KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de TECHNICAL MAINTENANCE DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE OPERATIONS! The unit must undergo technical maintenance 3 to 4 times a year. Maintenance includes general cleaning of the unit and the following operations: 1. Filter maintenance (3-4 times per year). Dirty filters increase air resistance in the system and reduce supply air volume.
  • Page 19: Troubleshooting

    KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de 5. Technical maintenance of air duct system (every 5 years). Even regular fulfilling of all the prescribed above maintenance operations may not completely prevent dirt accumulation in the air ducts which reduces the unit capacity. Duct maintenance means regular cleaning or replacement. 6.
  • Page 20: Storage And Transportation Regulations

    KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de STORAGE AND TRANSPORTATION REGULATIONS • Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range von +5 ˚С bis +40 ˚С and relative humidity up to 70 %. •...
  • Page 21: Manufacturer's Warranty

    KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de MANUFACTURER’S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC.
  • Page 22 KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de...
  • Page 23: Certificate Of Acceptance

    KOMFOrt EC S(B)200/250(-E) www.blaubergventilatoren.de CERTIFICATE OF ACCEPTANCE Unit Type Air handling unit Model KOMFORT EC S_____________ Serial Number Manufacture Date Quality Inspector’s Stamp SELLER INFORMATION Seller Address Phone Number E-mail Purchase Date This is to certify acceptance of the complete unit delivery with the user’s manual. The warranty terms are acknowledged and accepted.
  • Page 24 www.blaubergventilatoren.de B106-5EN-05...