Advanced Options
There are some additional configuration options that can be changed using the Alert-iT Profile Editor. Once the
device has been connected to a computer running the software (Available via our website) using a micro-USB cable
(not provided), the following options can be changed;
Latched Relay Output [Default = Disabled]. The wired output is pulsed for 2 seconds every 2 minutes by default,
enabling this option latches the relay permanently until the alarm is cleared. Note: This will significantly reduce the
backup battery life if the wired output is left active for long periods of time and the mains power is off.
Fault Code Warnings [Default = Enabled]. By default all fault codes received from paired monitors will trigger the
wired output. Disabling this feature will mean fault codes do not trigger the wired output. It is not recommended to
disable this feature.
Sounds [Default = Enabled]. There is an internal piezo sounder that will alert the user to various fault conditions.
Hidden Lights [Default = Disabled]. The LED's on the front of the unit can be unwanted by users, especially at
night if the unit is fitted in a bedroom. Enabling this option will hide the LED's after 1 minute. Briefly pressing the
"Wake/Clear" button on the bottom of the unit will wake up the LED's for 1 minute.
A "Discreet Mode" can be activated by holding the "Wake/Clear" button on power up. To do this, unplug
the mains adapter and remove one of the batteries. Press and hold the "Wake/Clear" button, insert the
battery, then release the button. All the LED's will now be hidden until the "Wake" button is tapped again, at
which point the LED's will then 'wake-up' for 1 minute. In this mode sounds are also disabled. To revert to
defaults, unplug the power jack, then remove and reinsert the batteries.
Alternatively for repeat orders or regular customers please let us know if you would like any of these features
enabled and we can configure the unit for you before shipment.
20
Need help?
Do you have a question about the Companion Mini and is the answer not in the manual?
Questions and answers