Pedigo WARMWATCH P-2148 Operation & Care Manual

Combination blanket/fluid warming cabinet

Advertisement

OPERATION & CARE
MANUAL
P-2148
P-2140
P-2145
P-2145
WARMWATCH® COMBINATION
BLANKET/FLUID WARMING CABINET
OPERATION & CARE
.
.
.
M M - 1 0 6 8 ( M N - 2 9 6 1 7 ) • R e v 0 ( 1 0 / 1 5 )
P R I N T E D I N U
S
A

Advertisement

Table of Contents
loading

Summary of Contents for Pedigo WARMWATCH P-2148

  • Page 1 OPERATION & CARE MANUAL P-2148 P-2140 P-2145 P-2145 WARMWATCH® COMBINATION BLANKET/FLUID WARMING CABINET OPERATION & CARE M M - 1 0 6 8 ( M N - 2 9 6 1 7 ) • R e v 0 ( 1 0 / 1 5 ) P R I N T E D I N U...
  • Page 2: Table Of Contents

    T A B L E C O N T E N T S Environmental Conditions ......1 Delivery .
  • Page 3: Environmental Conditions

    T R A N S P O R T A T I O N D A M A G E & C L A I M S All Pedigo Products, Inc. equipment is sold 3. Note all damage to packages directly on the carrier’s F.O.B. shipping point, and when accepted delivery receipt.
  • Page 4: Unpacking & Set-Up

    Unpacking & Set-up U N P A C K I N G A N D S E T - U P • • Carefully remove the appliance from the carton DO NOT DISCARD THIS MANUAL. or crate. This manual is considered to be part of the appliance and is to be provided to the NOTICE: Do not discard the carton or other owner or manager of the business or to the...
  • Page 5: Safety Procedures And Precautions

    Safety Procedures and Precautions S A F E T Y P R O C E D U R E S A N D P R E C A U T I O N S Knowledge of proper procedures is essential to the safe 1.
  • Page 6: Installation Preparation

    Preparation Installation Electrical Information P R E P A R A T I O N Before operating the unit, clean both the interior and exterior of the unit with a damp cloth and Wipe dry with a clean cloth or air dry. mild soap solution.
  • Page 7: General Information

    General Information G E N E R A L I N F O R M A T I O N This warming cabinet is designed to safely warm and store P-2148 INFORMATION: blankets and either irrigation uids or injection uids. The blanket warming chamber includes a white, epoxy-coated blanket support assembly and two (2) shelves.
  • Page 8: Dimensions

    Dimensions P - 2 1 4 8 D I M E N S I O N S 4.10" (104.0mm) CORD 1.7" (43.0mm) CORD PIVOT 29.8" (756mm) RADIUS 21.7" (550mm) 30.1" (764mm) WITH HANDLE CORD LENGTH 0.5" 19.4" (493mm) 8' (2,438mm) (est.) (14mm) 12.5"...
  • Page 9 P - 2 1 4 0 D I M E N S I O N S 54.6" (1387mm) 7.5" (189mm) 11.2" (285mm) CORD LENGTH 8' (2,438mm) (est.) 17.1" 33.1" (841mm) (434mm) 22.1" (561mm) 35.1" (891mm) 28.9" (735mm) 22.3" (566mm) TIMER 9.8"...
  • Page 10 P - 2 1 4 5 D I M E N S I O N S 4.0" (102mm) CORD LENGTH 8' (2,438mm) (est.) 4.6" (117mm) 27.1" (689mm) 25.4" (646mm) 30.2" (767mm) ERROR TIME START STOP TIMER OVER TEMP LOCK OVERTEMP LOCK 12.5"...
  • Page 11: General Warnings

    General Warnings G E N E R A L W A R N I N G S WARNING The unit requires special precautions regarding EMC A risk of increased emissions or decreased immunity (Electromagnetic Compatibility) and needs to be installed may result if the power cord attached is altered or a and put into service according to the EMC information manufacturer supplied power cable is not used.
  • Page 12: Guidance And Manufacturer's Declaration

    Guidance and Manufacturer’s Declaration Guidance and manufacturer’s declaration - electromagnetic emissions The unit is intended for use in the electromagnetic environment speci ed below. The customer or the end user of this unit should assure that it is used in such an environment. Compliance IEC 60601 test Immunity test...
  • Page 13: Operating Instructions

    Blanket Control Features Operating Instructions B L A N K E T C O N T R O L F E A T U R E S THERMOSTAT CONTROL AND L.E.D. DISPLAY Press the ON/OFF button once to acknowledge that the TIME START STOP...
  • Page 14: Blanket Chamber Operational Procedures

    Blanket Chamber Operational Procedures B L A N K E T C H A M B E R O P E R A T I O N A L P R O C E D U R E S 1. The appliance must be plugged into an appropriate WA R N I N G hospital grade receptacle as speci ed on the electrical information page.
  • Page 15: Warmwatch® Fluid Control Features

    WarmWatch® Fluid Control Features F L U I D C O N T R O L F E A T U R E S WarmWatch ® L.E.D. DISPLAY STATUS INDICATORS THERMOSTAT CONTROL AND L.E.D. DISPLAY MAIN DISPLAY OVERTEMP STATUS USB DOWNLOAD STATUS POINT INDICATOR L...
  • Page 16 F L U I D C O N T R O L F E A T U R E S WarmWatch ® CONTROL LOCK PROGRAMMING DOOR ALARM The warmer control can be locked so that no changes “dOOR” will appear on the display when the door is can be made to the temperature set-point or the mode opened.
  • Page 17: Fluid Chamber Operational Procedures

    Fluid Chamber Operational Procedures F L U I D C H A M B E R O P E R A T I O N A L P R O C E D U R E S 1. The appliance must be plugged into an appropriate NOTICE: The warmer is designed to warm uids to the hospital grade receptacle as speci ed on the electrical appropriate temperature recommended by your...
  • Page 18: Warmwatch® Usb Download Operation

    WarmWatch® USB Download Operation U S B D O W N L O A D O P E R A T I O N WarmWatch ® WarmWatch uid warmers records cavity temperature data THERMOSTAT CONTROL AND L.E.D. DISPLAY ® MAIN DISPLAY one time every hour.
  • Page 19: Warmwatch® Usb Download Reports

    WarmWatch® USB Download Reports U S B D O W N L O A D E D R E P O R T S WarmWatch ® REPORT INFORMATION ACCURACY .TXT REPORT EXAMPLE The raw data report downloaded to the USB ash drive by 20080307.TXT WarmWatch is written in a comma delimited (CSV) format.
  • Page 20: Care And Cleaning Cleaning And Preventative Maintenance

    Cleaning and Preventative Maintenance Care and Cleaning C L E A N I N G A N D P R E V E N T I V E M A I N T E N A N C E PROTECTING STAINLESS STEEL, EPOXY COATED AND CLEANING MATERIALS Cleaning can usually be accomplished with the proper cleaning PLASTIC SURFACES...
  • Page 21: Clean The Unit Regularly

    Clean the Unit Regularly C A R E A N D C L E A N I N G The cleanliness and appearance of this equipment will contribute considerably to its operating efficiency. Make certain the cabinet and door gasket are kept free of any debris that may accumulate.
  • Page 22: Service

    Trouble Shooting Guide Service NOTICE: If your unit is not operating properly, check the following before calling your authorized service agent. Check the power applied to the unit. Is the plug in outlet? Is the power circuit breaker switch in rear of unit OK? Has the high limit manual reset tripped? If so, reset.
  • Page 23: Accessory Service Parts List

    Accessory service parts list Heating cable replacement kits SERVICE A C C E S S O R Y S E R V I C E P A R T S L I S T * *NOT SHOWN ACCESSORY SERVICE PARTS EC1260BL P-2148 EC1540BL...
  • Page 24: Full Assembly Parts List And Views

    full assembly parts list and views SERVICE - FULL ASSEMBLY PARTS LIST ( D R AWI NGS SH OWN ON THE FOLLOWIN G P AG E S DESCRIPTION P-2148 P-2140 P-2145 INTERIOR FAN HOUSING/GUARD 1010254 1012557 1010844 FAN BLADE E3045FA FA-34603 E3045FA THERMOSTAT, MANUAL RESET, FLUID...
  • Page 25 SERVICE P-2148 FULL ASSEMBLY VIEW PART NUMBERS AND DRAWINGS ARE SUBJECT TO CHANGE WITHOUT NOTICE. MM-1068 (MN-29617) • Rev 0 (10/15) • WarmWatch® Combination Blanket/Fluid Warmer • 23...
  • Page 26 SERVICE P-2140 FULL ASSEMBLY VIEW PART NUMBERS AND DRAWINGS ARE SUBJECT TO CHANGE WITHOUT NOTICE. MM-1068 (MN-29617) • Rev 0 (10/15) • WarmWatch® Combination Blanket/Fluid Warmer • 24...
  • Page 27 SERVICE P-2145 FULL ASSEMBLY VIEW PART NUMBERS AND DRAWINGS ARE SUBJECT TO CHANGE WITHOUT NOTICE. MM-1068 (MN-29617) • Rev 0 (10/15) • WarmWatch® Combination Blanket/Fluid Warmer • 25...
  • Page 28: Electrical Parts List & Views

    Electrical parts list & views SERVICE ELECTRICAL VIEW PARTS LIST DESCRIPTION P-2148 P/N P-2140 P/N P-2145 P/N THERMOSTAT, AUTO HI-LIMIT UPPER E3040TT TT-34350 E3040TT LOWER TT-34350 E3040TT TT-34350 OVERLAY, V-DRIVE PE-28735 PE-28735 PE-28735 FILTER, ELECTRONIC NOISE FI-34625 FI-34625 FI-34625 BEEPER, SOLID STATE BP-3567 BP-3567 BP-3567...
  • Page 29 SERVICE P-2140 ELECTRICAL VIEW P-2148/P-2145 ELECTRICAL VIEW PART NUMBERS AND DRAWINGS ARE SUBJECT TO CHANGE WITHOUT NOTICE. MM-1068 (MN-29617) • Rev 0 (10/15) • WarmWatch® Combination Blanket/Fluid Warmer • 27...
  • Page 30 refer to wire diagram included with the unit (under top lid) Wire Diagrams Refer to wire diagram included with the unit. MM-1068 (MN-29617) • Rev 0 (10/15) • WarmWatch® Combination Blanket/Fluid Warmer • 28...
  • Page 31 Refer to wire diagram included with the unit. MM-1068 (MN-29617) • Rev 0 (10/15) • WarmWatch® Combination Blanket/Fluid Warmer • 29...
  • Page 32 Refer to wire diagram included with the unit. MM-1068 (MN-29617) • Rev 0 (10/15) • WarmWatch® Combination Blanket/Fluid Warmer • 30...
  • Page 33: Warranty

    PEDIGO PRODUCTS, INC LIMITED WARRANTY Pedigo Products, Inc. warrants to the original purchaser that any original part that is found to be defective in material or workmanship will, at our option, subject to provisions hereinafter stated, be replaced with a new or rebuilt part.

This manual is also suitable for:

Warmwatch p-2140Warmwatch p-2145

Table of Contents