IDEAL 700 Series Manual page 4

200 amp clamp meters

Advertisement

To Measure AC Current:
1. Set the rotary switch to the appropriate AAC range.
2. With the jaws closed, separate one wire from a bundle using
the long fixed jaw.
3. Slide the wire to the corner where the two jaws meet, then
open the jaws to let it in.
4. Measure the current in only one wire at a time.
AC & DC Volts
AC Voltage
Range Resolution
Max
Display
2000mV
1mV
1999
200V
0.1V
199.9 ±(1.2%+3)
750V
1V
750
Frequency response: 50Hz - 500Hz; ±(2%+5) 500Hz - 1KHz;
50Hz - 500Hz on 600V and 750V ranges.
True RMS Sensing: (61-704 only)
7
Accuracy
±(1.2%+3)
±(2%+5)
DC Voltage
Range Resolution
Max
Display
2000mV
1mV
1999
200V
0.1V
199.9 ±(0.5%+1)
1000V
1V
1000
To Measure Voltage:
5. Plug the black test lead into the COM port and the red test
lead into the + port.
6. Set the rotary switch to appropriate VAC or VDC range.
7. Connect the meter in parallel with the load or circuit.
8. Measure the voltage
Frequency
To Measure Frequency:
1. Plug the black test lead into the COM port and the red test
lead into the + port.
2. Set the rotary switch to the HZ position.
3. Connect the meter in parallel with the load or circuit.
4. Meter is auto-ranging, and will select 2k 20k or 40k range.
5. Measure the frequency.
8
Accuracy
±(0.5%+1)
±(0.5%+1)