Download Print this page

IDEAL 700 Series Manual page 6

200 amp clamp meters

Advertisement

Continuity Check
To Verify Continuity:
A continuity test ensures that all circuit connections are intact.
1. Plug the Black test lead into the COM port and the Red test
lead into the + port.
2. Set the rotary switch to the
3. Connect the test leads to the circuit to be measured. The
beeper will sound within 100mS if the resistance of the
circuit measured is lower than 300 Ohms.
4. In addition to the beeper, both 61-702 and 61-704 have an
LED to verify continuity.
General Specifications
Display:
3-1/2 digit LDC display
Polarity Indication:
Automatic, negative indicated,
positive implied
Overrange Indication:
"OL"
Low Battery Indication:
drops below operating voltage
Auto Power Off:
Approx. 60 min.
Temperature Coefficient: 0.1 x (specified accuracy) /
°F, <64°F or >82°F
Power Requirements:
9V NEDA 1604
Battery Life:
150 hours typical with alkaline
75 hours typical with carbon zinc
Installation Category:
IEC 1010-1, IEC1010-2-032,
Cat III 1000V
C
US
Maintenance
Warning
To avoid electrical shock, remove test lead before opening
the cover. Repairs or servicing not covered in this manual
should only be performed by qualified personnel.
11
position.
when the battery voltage
Battery Replacement:
When the multimeter displays
replaced. Disconnect and unplug leads, turn meter off, and
remove the battery cover. Replace the battery with a NEDA type
1064 9V battery.
Warranty Statement
This tester is warranted to the original purchaser against defects
in material and workmanship for two years from the date of
purchase. During this warranty period, IDEAL INDUSTRIES, INC.
will, at its option, replace or repair the defective unit, subject to
verification of the defect or malfunction.
This warranty does not apply to defects resulting from abuse,
neglect, accident, unauthorized repair, alteration, or unreasonable
use of the instrument.
Any implied warranties arising out of the sale of an IDEAL
product, including but not limited to implied warranties of mer-
chantability and fitness for a particular purpose, are limited to
the above. The manufacturer shall not be liable for loss of use
of the instrument or other incidental or consequential damages,
expenses, or economic loss, or for any claim or claims for such
damage, expenses or economic loss.
State laws vary, so the above limitations or exclusions may not
apply to you. This warranty gives you specific legal rights, and
you may also have other rights which vary from state to state.
IDEAL INDUSTRIES, INC.
Sycamore, IL 60178, U.S.A.
800-304-3578 Customer Assistance
www.testersandmeters.com
ND 2356-3
Made in Taiwan
the battery must be

Advertisement

loading

This manual is also suitable for:

61-70261-704