5
System Set Up

5.2 Connecting inputs/outputs

When the wires are wired to adjacent terminals use ring terminals and insulate the wires.
F2
F1
10A 250V
6.3A 250V
1
Note: Before connecting a wire to the TBI.1, confirm that the power supply earth cable is securely
CN01
2
(WHT)
1
CNP1
4
6
(WHT)
3
CN3C
1
(YLW)
2
1
CNPA
3
(RED)
TAB1
1
TBO.1
2
LED1
3
4
1
1
SW4
CN1A
(WHT)
6
4
1
CNPWM
1
(WHT)
3
SW3
1
CNV1
CNPWM3
1
8
(WHT)
(RED)
3
1
5
LED2
SW2
LED3
CNRF
1
8
(WHT)
1
5
CN105
1
CNBHT
1
SW1
(RED)
(BLK)
5
4
1
8
CNIT
1
CNBH
(BLU)
CNOUT
2
5
(WHT)
(WHT)
LED4
CN108
4
7
CNOUC
1
1
CNBC
(BLU)
(GRY)
3
3
CN2A
CN22
(BLU)
1
(BLU)
1
1
1
1
1
2
4
6
8
10
12 14
2
1
1
3
5
7
9
11
13
CN20
2
4
4
5
5
5
XBL
XBN
(RED)
TBI.1
CN2B
CNW3
CNW12
CNW5
(YLW)
(BLU)
(RED)
(WHT)
<Figure 5.2.1>
Signal inputs
Name Terminal block Connector Item
IN1
TBI.1 3-4
Room thermostat 1 input
IN6
TBI.1 1-2
Room thermostat 2 input
IN8
TBI.1 5-6
Electric energy meter 1
IN9
TBI.1 7-8
Electric energy meter 2
IN10
TBI.1 9-10
Heat meter
*1. Connectable electric energy meter and heat meter
Voltage free contact for 12VDC detection by FTC (TBI.1 5, 7 and 9 pins have positive voltage.)
Minimum ON time: 40ms
Minimum OFF time: 100ms
0.1 pulse/kwh
1
pulse/kwh
100 pulse/kwh
1000 pulse/kwh
Those values can be set by the main controller. (Refer to the menu tree in "5.7 Main Controller".)
Wiring specification and local supply parts
Item
Name
Model and specifications
Signal input
Signal input
Use sheathed vinyl coated cord or cable.
function
wire
Max. 10 m
Wire type: CV, CVS or equivalent
Wire size: Stranded wire 0.13 mm² to 1.25 mm²
Solid wire: ø0.4 mm to ø1.2 mm
Switch
Non-voltage "a" contact signals
Remote switch: minimum applicable load 12V DC, 1mA
Thermistor inputs
Name
Terminal block Connector
Item
TH1
CN20
Thermistor (Room temp.) (Option)
Ensure to wire thermistor wirings away from the power line and/or OUT3 to 13 wirings.
Do not splice the wiring to extend or shorten it, otherwise this could affect correct monitoring of each temperature.
If the wiring is too long, bundle it with a strap to adjust the length in the cylinder unit.(see the photograph on the right)
*1. The maximum length of the thermistor wiring out of the cylinder unit is 5 m.
When the wires are wired to adjacent terminals, use ring terminals and electrically insulate the wires.
18
connected and prevent the FTC from being applied with static electricity (e.g. touch a case body etc.).
Otherwise, it may cause a failure of the FTC due to the static electricity.
OFF (Open)
ON (Short)
Refer to SW2-1 in <5.1 DIP Switch Functions>.
Refer to SW3-1 in <5.1 DIP Switch Functions>.
*1
10
pulse/kwh
Optional part model
PAC-SE41TS-E
5
System Set Up
Outputs
Name
Terminal block Connector Item
OFF
OUT3
TBO.1.1-2
2-way valve 2b output *1
OFF
OUT13
TBO.1.3-4
2-way valve 2a output *1
OFF
*1 For 2-zone valve ON/OFF control.
N
L N
L
1 2 3 4
TBO.1
OUT3 OUT13
How to use TBO.1
Wiring specification and local supply parts
Item
Name
Model and specifications
External output function
Outputs wire
Use sheathed vinyl coated cord or cable.
Max. 30 m
Wire type: CV, CVS or equivalent
Wire size: Stranded wire 0.25 mm² to 1.5 mm²
Solid wire: ø0.57 mm² to ø1.2 mm²
Note:
1. Stranded wire should be processed with insulation-covered bar terminal (DIN46228-4 standard compatible type).
ON
Signal/Max current
Max. total current
ON
230V AC 0.1A Max.
0.2A
ON
230V AC 0.1A Max.
Tool
Tool
Conductor
Conductor
Outline view
Top view
Connect them using either way as shown above.
<Figure 5.2.2>
19