Packing And Transporting; Return To Service Procedures - Saft 4579 Component Maintenance Manual With Illustrated Parts List

Nickel cadmium battery
Table of Contents

Advertisement

COMPONENT MAINTENANCE MANUAL
(2)
The battery temperature should be allowed to equalize to a range of 60°F
(15°C) to 90°F (32°C) before charging.
(3)
Charge the battery (Ref Fig 701).
(4)
Adjust the electrolyte level (TESTING and FAULT ISOLATION).
(5)
Perform a Capacity Check per instructions in TESTING and FAULT
ISOLATION under the section "Second Discharge".
(6)
Recharge the battery (TESTING and FAULT ISOLATION).
(7)
Repeat (if necessary) the above charge/discharge sequence until the unit
accepts a full charge and delivers its rated capacity.
STORAGE TIME
Less than 3 months
More than 3 months
F.

Packing and Transporting

The normal packing for shipment of Saft Ni-Cd batteries is with fiberboard or injected
foam packing enclosed in fiberboard or wooden outer containers. For overseas
shipments, wrapping in sealed plastic is recommended. Precautions must be taken to
keep batteries upright while in transit. All markings and documentation should
conform to current IATA regulations (UN2795 or UN2800 as applicable) governing
the shipment of vented Ni-Cd batteries.
SAFT AMERICA INC.
4579
Charge the battery (TESTING and FAULT
ISOLATION).
Perform electrical tests and charge the battery
(TESTING and FAULT ISOLATION).

Return to Service Procedures

Figure 701
SERVICE PROCEDURE
24-31-05
PAGE 705
Jan 30/98

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Saft 4579

Table of Contents