Advertisement

SFC4000HP_V5-P Hardware Installation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SFC4000HP V5-P and is the answer not in the manual?

Questions and answers

Summary of Contents for Soltech SFC4000HP V5-P

  • Page 1 SFC4000HP_V5-P Hardware Installation Manual...
  • Page 2: Table Of Contents

    Table of Contents Table of Contents Chapter 1 SFC4000HP_V5-P Introduction........................1 1.1 Appearance Description for Standard Configuration..............1 1.2 SFC4000HP_V5-P Systematic Characteristic Parameters............3 Chapter 2 Installation Preparation........................ 4 2.1 Caution of Usage..........................4 2.2 Safety Advice............................. 4 2.2.1 Safety Principles........................4 2.2.2 Safety Notices........................
  • Page 3 Table of Contents Chapter 4 Maintaining Switch........................15 4.1 Opening the Machine Box......................15 4.2 Closing the Machine Box.......................16 Chapter 5 Hardware Fault Analysis......................18 5.1 Fault Separation..........................18 5.1.1 Faults Relative with Power and Cooling System............18 5.1.2 Faults Relative with Port, Cable and Connection............18 5.2 Indicator Description........................19 - II -...
  • Page 4: Chapter 1 Sfc4000Hp_V5-P Introduction

    SFC4000HP_V5-P Hardware Installation Manual Chapter 1 SFC4000HP_V5-P Introduction The section describes the characteristics and parameters of SFC4000HP_V5-P and give s an overview of SFC4000HP_V5-P. 1.1 Appearance Description for Standard Configuration The built-in ports of SFC4000HP_V5-P are: 24 gigabit TX ports and 4 Combo ports and 1 CLI.
  • Page 5 SFC4000HP_V5-P Hardware Installation Manual each port Always on in green: 1000M Off: no signal transmission Always on in orange: PD is connected and PoE works well POE indicator Off: PD is not connected and PoE does not provided. Always on in green: 1000M Link/Act indicator on the 25T/S-28 combo port...
  • Page 6: Sfc4000Hp_V5-P Systematic Characteristic Parameters

    SFC4000HP_V5-P Hardware Installation Manual 1.2 SFC4000HP_V5-P Systematic Characteristic Parameters Memory Flash: 16M Bytes; Memory: 128M Bytes; Standard 24 gigabit TX ports; configuration 4 TX/SFP ports 1 CLI port Dimensions mm 440×208×44 (W×D×H) Operating 0℃~45℃; 10%~90% non-condensing Hardware temperature/ characteris humidity tics Storage -40℃~70℃;...
  • Page 7: Chapter 2 Installation Preparation

    SFC4000HP_V5-P Hardware Installation Manual Chapter 2 Installation Preparation 2.1 Caution of Usage Similar to other electronic products, the semiconductor chip easily gets damaged if you power o n or off abruptly and frequently. To restart up the switch of SFC4000HP_V5-P, you have to open t he power on-off after the power is cut down for three to five seconds.
  • Page 8: Safety Notices

    SFC4000HP_V5-P Hardware Installation Manual Put on the protective glasses if the environment may cause damage to your eyes.  Avoid incorrect operations that may cause damage to human or devices.  Safety Notices The safety notices mentioned here means that improper operation may lead to bod y damage.
  • Page 9: Electrostatic Discharge Damage Prevention

    SFC4000HP_V5-P Hardware Installation Manual 1)Check potential dangers, such as the humid floor, ungrounded extensible power line and ta tty power line. 2)Install the emergent on-off at the working room for turning off the power when trouble happ ens. 3)Turn off the power on-off of the switch and plug off the power line before installing or uninst alling the machine box or working beside the power.
  • Page 10: Environment

    SFC4000HP_V5-P Hardware Installation Manual Environment The switch can be installed on the desk or the cabinet. The location of the machine bo x, cabinet planning and indoor cabling are very important for normal system ’ s func tion. Short distance between devices, bad ventilation and untouchable control plate wi ll cause maintenance problems, systematic faulty and breakdown.
  • Page 11: Power Requirements

    SFC4000HP_V5-P Hardware Installation Manual The clapboard separates exhaust gas and inflow air, and boost cool air to flow in the  machine box. The best location of the clapboard is decided by the air flow mode in the machine box, which can be obtained through different location tests. 2.3.4 Power Requirements Make sure that the power supply has nice grounding and the power at the input side of the swit ch is reliable.
  • Page 12: Chapter 3 Installing The Sfc4000Hp_V5-P Switch

    SFC4000HP_V5-P Hardware Installation Manual Chapter 3 Installing the SFC4000HP_V5 -P Switch Caution: Only professionals are allowed to install or replace the devices. 3.1 Installation Flow of SFC4000HP_V5-P 2. Installing the Machine Box of the Switch The installation of the machine box has two modes: ...
  • Page 13: Installing The Machine Box On The Desk

    SFC4000HP_V5-P Hardware Installation Manual Installing the Machine Box on the Desk The SFC4000HP_V5-P switch can be directly put on the smooth and safe desk. Note: Do not put things weighing 4.5 kg or over 4.5 kg on the top of the switch. Installing the Machine Box on the Cabinet The machine box of the switch is fixed on the cabinet through the brackets.
  • Page 14: Connecting The Ports

    SFC4000HP_V5-P Hardware Installation Manual 3. Connecting the Ports Connecting the Console Port The switch of SFC4000HP_V5-P has a console port. The rate of the console port is 9600bps. It has a standard RJ45 plug. After you conne ct the console port to the serial port of PC through a console cable, you can configure and monitor the switch of SFC4000HP_V5-P by running the terminal emulation softwa re, such as super Windows terminal.
  • Page 15: Connecting Gsfp Ports

    SFC4000HP_V5-P Hardware Installation Manual Table 3- 1 Pins of the console port Name Remarks Input Output Note: The console port of SFC4000HP_V5-P does not support traffic control. Therefore, you must set the option data traffic control to none when you configure the switch with the super terminal.
  • Page 16: Connecting Ethernet Tx Ports

    SFC4000HP_V5-P Hardware Installation Manual 3.3.3 Connecting Ethernet TX Ports The SFC4000HP_V5-P switch has 24 10/100/1000Base-T ports and their correspondi ng indicators 1 to 24, used for indicating the state of port Link/ACT/Speed. To use the electrical port, you can connect the electrical port and other Ethernet devices with the direct-through or cross cable through the UTP port.
  • Page 17: Checking After Installation

    SFC4000HP_V5-P Hardware Installation Manual Sending/receiving the normal phase of data 0 TP0+ Sending/receiving the paraphase of the data 0 TP0- Sending/receiving the normal phase of data 1 TP1+ Sending/receiving the normal phase of data 2 TP2+ Sending/receiving the paraphase of the data 2 TP2- Sending/receiving the paraphase of the data 1 TP1-...
  • Page 18: Chapter 4 Maintaining Switch

    SFC4000HP_V5-P Hardware Installation Manual Chapter 4 Maintaining Switch Caution: Before opening the machine box, make sure that you have released the static you carried and then turn off the power on-off of the switch. Before operating any step in Appendix B, read the section “Safety Advice”. Before performing operations beside the power supply or on the machine box, turn off the power on-off and plug out the power cable.
  • Page 19: Closing The Machine Box

    SFC4000HP_V5-P Hardware Installation Manual Open the cover by holding two sides of the cover towards the direction of the arrow ke y shown in the following figure: When the cover is opened, put it aside. The mainboard of the system appear Note: After taking off the cover, put it horizontally and avoid it to be crushed or collided.
  • Page 20 SFC4000HP_V5-P Hardware Installation Manual Nail the bolt and screw it tightly with the screwdriver. Reinstall the switch on the cabinet or the desk. Reconnect all cables of the switch. - 17 -...
  • Page 21: Chapter 5 Hardware Fault Analysis

    SFC4000HP_V5-P Hardware Installation Manual Chapter 5 Hardware Fault Analysis The part describes how to remove the fault from the switch. 1. Fault Separation The key for resolving the systematic faults is to separate the fault from the system. Yo u can compare what the system is doing with what the system should do to detect the fault.
  • Page 22: Indicator Description

    SFC4000HP_V5-P Hardware Installation Manual If the power on-off is at the “ON” location, check the power supply and the power cable  If the console port does not work after the system is started up, check whethe  r the console port is set to a baud rate of 9600 bps, eight data bits, no sum ch eck bit, one stop bit and no traffic control.
  • Page 23 SFC4000HP_V5-P Hardware Installation Manual Copyright Claims Without the written approval of the company , any person or group cannot transcribe, copy or change partial or all contents of this manual, and must not broadcast it in any manner. Trademark claims Trademarks, product names, service names and company names, which are written i n this manual but do not belong to the company, belong to their owners respectively.

Table of Contents