2.4 Installation Tools and Device...................... 7 Chapter 3 Installing the SFC410HP Switch....................3.1 Installation Procedures of SFC410HP..................8 3.2 Installing the Chassis of SFC410HP..................... 8 3.2.1 Installing the Chassis on the Desk..................8 3.2.2 Installing the Chassis on the Cabinet................8 3.3 Connecting the Port........................9...
The document describes the characteristics and parameters of SFC410HP and gives an o verview of SFC410HP. 1.1 Standard Configuration SFC410HP switch has three parts: 8 IEEE802.3af/at gigabit Ethernet TX ports, 2 gigabit E thernet SFP ports and 1 Console port. See the following table: Table 1- 1 Attributes of necessary ports...
Page 4
Realizes the forward of gigabit Ethernet 2 SFP ports optical signals. Besides, SFC410HP provides with a grounding column, a power socket, and a silent fan. Figure 1- 2 Back template of the SFC410HPswitch Table 1-3 Parts at the rear template of the SFC410HP switch Abbrev.
SFC410HP Hardware Installation Manual 1.2 Characteristic Parameters of SFC410HP IEEE 802.1d Spanning Tree Protocol IEEE 802.1p Class of Service IEEE 802.1q tagged VLAN IEEE 802.3x Flow control Supported standard IEEE 802.3ad Link aggregation IEEE 802.3af Power via Media Dependent Interface Protocol IEEE 802.3at DTE Power Enhancements...
Similar to other electronic products, the semiconductor chip easily gets damaged if you power on and off abruptly and frequently. To restart up the switch of SFC410HP, you have to open the power on-off three or five seconds after the power is cut off.
This part describes the requirements for the installation locations. Environment SFC410HP switch adopts the wall-mounted installation mode. The switch has no fan, so a n environment with good ventilation is needed for the heat cooling of the switch. For location planning and device locating, refer to section 2.3.2 “Location Configuration Pr evention”.
Installation Tools and Device The tools and devices to install the SFC410HP switch are not provided by the SFC410HP switch. You yourself need to prepare them. The following are the tools and devices needed for the typical installation of the SFC410HP switch: ⚫...
⚫ Installing the Chassis on the Cabinet Installing the Chassis on the Desk The SFC410HP switch can be directly put on the smooth and safe desk. Note: Do not put things weighing 4.5 kg or over 4.5 kg on the top of the switch.
Connecting the Port Connecting the Console Port The switch of SFC410HP has a Console port. The rate of the console port is a value of 12 00bps—115200bps. It has a standard RJ45 plug. After you connect the console port to the seri al port of PC through a console cable, you can configure and monitor the switch of SFC410HP by running a terminal emulation software, such as super Windows terminal.
Page 12
The cable is used to connect the console port of the SFC410HP switch and the out side console terminal device. One end of the cable is a 8-pin RJ45 plug and the ot her end is a 25-hole plug (DB25) and a 9-hole plug (DB9).
3.3.2 Connecting the SFP Ports SFC410HP provides 2 gigabit SFP optical ports. Each port corresponds to one indicator re spectively, which is used for indicating the port Link/ACT state. When the indicator is always on , the link is normal; when it flickers, the data receives and forwards. To use the optical port, you need connect it to the SFP optical module, and then to other Ethernet terminal devices through an optical fiber.
3.3.3 Connecting Gigabit Ethernet TX Ports The SFC410HP switch has 8 10/100/1000 Base-TX ports. Each port has one indicator, whi ch indicates the state of Link/ACT. If the indicator is always on, the port is linked up; if the indica tor flickers, the data is transmitted on the port.
⚫ Check whether the connected power supply meets the power requirements of the switch. ⚫ Check whether the grounding line of SFC410HP is correctly connected. C ⚫ heck whether SFC410HP is correctly connected to other terminal devices. - 13 -...
Caution: Before opening the chassis, make sure that you have released the static you carried and then turn off the power on-off of SFC410HP. Before operating an y step in Appendix B, read the section “SafetyAdvice”. Before performing operations beside the power supply or on the chassis, tur n off the power on-off and plug out the power cable.
Page 17
SFC410HP Hardware Installation Manual Following the directions shown on the above-mentioned figure, install the cover and bottom of the frame box. Nail the bolt and screw it tightly with the screwdriver. Reinstall the switch on the DIN rail or on the desk.
SFC410HP Hardware Installation Manual Chapter 5 Hardware Fault Analysis The part describes how to remove the faults from the switch. 5.1 Fault Separation The key for resolving the systematic faults is to separate the fault from the system. You ca n compare what the system is doing with what the system should do to detect the fault.
Page 19
SFC410HP Hardware Installation Manual If the indicator is always on, it means that the connection is linked. LINK/ACT port indicators If the indicator is off, the port is not linked. If the indicator is always on, it means the indicator PoE works.