Technical Data; Measuring Functions; Engine Test; Multimeter - Bosch FSA 720 Instruction Manual

Vehicle system analysis
Hide thumbs Also See for FSA 720:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16
8.

Technical data

8.1

Measuring functions

8.1.1

Engine test

Measuring functions
Speed
Oil temperature
U battery
U term. 15
U term. 1
Ignition voltage,
Spark voltage
Spark duration
Relative compression via starter current
U generator ripple
I starter
I generator
I spark plugs
I primary
Closing angle
Closing time
Ignition point,
Ignition advance with Stroboscope
Start-of-delivery, start of injection,
Timing:
With Stroboscope
Pressure (Air)
Pulse duty factor t-/T
Injection time
Glow time
8.1.2

Multimeter

Measuring functions
Speed
U battery
U term. 15
U-DC
min./max.
I-1000 A
I-30 A
Resistance
(R-Multi 1)
Pressure P-air
Oil temperature
Air temperature
Fluid pressure
The measuring range is greater than the permissible measurement voltage
1)
Robert Bosch GmbH
Measurement range
Resolution
450 rpm – 6000 rpm
10 rpm
100 rpm – 12000 rpm
10 rpm
250 rpm – 7200 rpm
10 rpm
100 rpm – 500 rpm
10 rpm
-20 °C – 150 °C
0,1 °C
0 – 60 V
0,1 V
0 – 60 V
0,1 V
0 – 20 V
50 mV
±500 V
1 V
±50 kV
100 V
0 – 6 ms
0,01 ms
0 – 200 Ass
0,1 A
0 – 200 %
0,1 %
0 – 1000 A
0,1 A
0 – 30 A
0,1 A
0 – 100 %
0,1 %
0 – 360 °
0.1 °
0 – 50 ms
0,01 ms
0,1 ms
0 – 60 °KW
0,1 °KW
0 – 60 °KW
0,1 °KW
-800 hPa – 1500 hPa
1 mbar
0 – 100 %
0,1 %
0 – 25 ms
0,01 ms
0 – 20 ms
0,01 ms
Measurement range
Resolution
as for engine test
0 - 60 V
0,01 V
0 - 60 V
0,1 V
1)
±200 mV – ±20 V
0,001 V
±20 V – ±200 V
0,01 V
1)
±1000 A
0,1 A
±30 A
0,01 A
0 – 1000 Ω
0,001 Ω
1 kΩ – 10 kΩ
0,1 Ω
10 kΩ – 999 kΩ
100 Ω
0,2 hPa – 2500 hPa
0,1 hPa
-20 °C – 150 °C
0,1 °C
-20 °C – 100 °C
0,1 °C
0 – 10000 hPa
10 hPa
Technical data | FSA 720 | 25
Sensors
Connecting cable B+/B–
Trigger clamp, Secondary sensor,
Primary connecting cable (UNI 4)
Current clamp 30A, Diesel clip-on sensor,
Current clamp 1000 A (starter current)
Oil temperature sensor
Connecting cable B+/B–
Primary connecting cable (UNI 4)
Primary connecting cable (UNI 4)
Primary connecting cable (UNI 4),
Secondary sensor
Primary connecting cable (UNI 4),
Secondary sensor
Primary connecting cable (UNI 4),
Secondary sensor
Multi measuring cable CH1
Current clamp 1000 A
Current clamp 30 A
Primary connecting cable (UNI 4)
Secondary sensor
Current clamp 30 A
Trigger clamp
Clip-on sensor
Air pressure sensor
Multi measuring cable CH1 / CH2
Multi measuring cable CH1 / CH2
Multi measuring cable CH1 / CH2
Sensors
Connecting cable B+/B–
Primary connecting cable (UNI 4)
Multi measuring cable CH1 / CH2
Current clamp 1000 A
Current clamp 30 A
Multi measuring cable CH1
Air pressure sensor
Oil temperature sensor
Air temperature sensor
Fluid pressure sensor,
Oil pressure sensor
1 689 979 894
en
|
2014-08-28

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents