Wayne GPS400 Operating Instructions And Replacement Parts List Manual

Engine driven centrifugal pump

Advertisement

Quick Links

See Warranty on page 8 for important information about commercial use of this product.
Operating Instructions and Replacement Parts List
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage!
Retain instructions for future reference.
Description
The Wayne pumps are general use
centrifugal water pumps. The pump is
®
equipped with a Viton
seal assembly
that is also compatible with many
agricultural chemicals.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
an imminently hazardous situation which,
if not avoided, WILL result in death or
serious injury.
a potentially hazardous situation which,
if not avoided, COULD result in death or
serious injury.
potentially minor or moderate injury.
important information, that if not
followed, may cause damage to
equipment.
General Safety
Information
CALIFORNIA PROPOSITION 65
or its power cord may contain chemicals
known to the State of California to
cause cancer and birth defects or other
reproductive harm. Wash hands after
handling.
REMINDER: Keep your dated proof of purchase for warranty purposes!
© 2007 Wayne Water Systems
Engine Driven
Centrifugal Pump
1. Know the pump application,
limitations, and potential hazards.
Read these rules and the instructions
carefully. Failure to follow them could
cause serious bodily injury and/or
property damage.
Never run engine in an
enclosed area. Exhaust gases
contain deadly poisonous
carbon monoxide, which has
no odor or taste.
Do not use to pump flammable
Danger
or explosive fluids such as
gasoline, fuel oil, kerosene, etc.
indicates
Do not use in flammable and/or
explosive atmospheres. Pump should only
be used with liquids compatible with pump
component materials. Failure to follow
Warning
this warning can result in personal injury
indicates
and/or property damage.
2. Observe all safety precautions for the
handling of the fuel.
Caution
indicates a
Do not refuel a hot engine. Fuel
Notic
spilled on a hot engine could
indicates
result in a fire or explosion. Do
not refuel a running engine.
3. Pump should be located and should
rest on a level solid foundation. Do
not suspend pump by means of the
discharge pipe.
This
secure footing so it doesn't fall over.
product
4. Do not use torches or apply excessive
heat, fire or flames to this pump as an
explosion may result.
Attach it to this manual or fi le it for safekeeping.
For parts, product & service information
visit www.waynepumps.com
5. Before working on the unit, insulate
the wire from the spark plug, by
disconnecting the spark plug wire from
the spark plug.
piping system MUST be protected against
below freezing temperature. Failure to do
so could cause serious damage and voids
the warranty.
6. Do not run pump dry. Water is
required to lubricate the shaft seal.
7. Pumping chemicals or corrosive liquids
with this pump may shorten the life of
the pump and may be hazardous to the
operator.
8. Personal Safety:
a. Wear safety glasses at all times when
working with pumps.
b. Keep work area clean, uncluttered
and properly lighted; replace all
unused tools and equipment.
c. Keep visitors at a safe distance from
the work area.
d. Make workshop child-proof with
padlocks, master switches, and by
removing starter keys.
9. This pump is designed for non-abrasive
fluid transfer; do not use as a trash
pump. Always use a suction strainer
with this pump to filter abrasive
material. Abrasive materials such as
sand and gravel will shorten the life of
the pump.
Be sure
pump is on
GPS400
Need
Assistance?
Call Us First!
1-800-237-0987
Complete
pump and
320602-001 7/07

Advertisement

Table of Contents
loading

Summary of Contents for Wayne GPS400

  • Page 1 5. Before working on the unit, insulate limitations, and potential hazards. the wire from the spark plug, by The Wayne pumps are general use Read these rules and the instructions disconnecting the spark plug wire from centrifugal water pumps. The pump is carefully.
  • Page 2: Installation

    Operating Instructions and Replacement Parts List Installation 4. A suction strainer is required to filter 12. Move the engine switch to ‘ON’ abrasive material. Abrasive material, position. This pump is designed to be self-priming such as gravel, will destroy the pump 13.
  • Page 3: Performance Information

    GPS400 Performance Information 2” Cast Iron Pump Performance CAPACITIES IN GALLONS PER HOUR Discharge Dynamic Suction Lift - Feet Head - Feet 6600 6420 6180 6000 5640 5220 6180 6000 5640 5220 4800 4380 5640 5220 4800 4380 4080 3660...
  • Page 4: Suction Hose

    Operating Instructions and Replacement Parts List For Pump Accessories, call 1-800-237-0987 Please provide following information: Address parts correspondence to: - Model number Wayne Water Systems - Serial number (if any) 101 Production Drive - Part description and number as shown Harrison, OH 45030...
  • Page 5 GPS400 For Replacement Parts, call 1-800-237-0987 Please provide following information: Address parts correspondence to: - Model number Wayne Water Systems - Serial number (if any) 101 Production Drive - Part description and number as shown Harrison, OH 45030 Item No.
  • Page 6 Operating Instructions and Replacement Parts List Notes www.waynepumps.com...
  • Page 7: Maintenance / Service Record

    GPS400 Maintenance / Service Record Date Maintenance Performed Replacement Components Required www.waynepumps.com...
  • Page 8 Limited Warranty For one year from date of purchase, Wayne Water Systems (”Wayne Water Systems“) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (”Product“) found upon examination by Wayne Water Systems to be defective in materials or workmanship.

Table of Contents