  • Page 1 WALLTHERM AIR® FREESTANDING WOOD FIRE INSTALLATION & OPERATION INSTRUCTIONS October 2014...
  • Page 2 Congratulations on the purchase of your Walltherm Air® Ultra Low Emission Burner, by Jayline. The Walltherm Air® Ultra Low Emission Burner is not a conventional wood fire, it is a ‘wood gasification stove’, developed for the optimal burning of air dried natural wood.
  • Page 3: Items Supplied With The Fire

    INSTAllATION OF yOuR WAllTHERm AIR® ulTRA lOW EmISSION BuRNER Walltherm Air® recommends you use a suitably qualified installation technician to install your fire. Your dealer or heating specialist will be able to help with recommendations as well as advise on permits/consents required for the installation in your area.
  • Page 4 The appliance can then be bolted to the floor protector with two 6mm x 50mm dynabolts or equivalent. October 2014 www.jayline.co.nz page 4...
  • Page 5 (hose/pipe & vents not supplied). Attention: Extractor hoods that are installed in the same room as the fire can cause problems. Attention: If there are other fireplaces near the Walltherm Air® fire, combustion air must be obtained from outside.
  • Page 6 The cable must be heat resistant. The electrical installation requires a (COC) Certificate of Compliance, obtained from the electrician. Electricity supply 20V / 50Hz REGULATOR THERMOSTAT HOT AIR FOR MIN BLOWER TEMPERATURE FIG 3. October 2014 www.jayline.co.nz page 6...
  • Page 7 TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS/NZS 401:1999 AND/OR CM1. . PLEASE ENSURE THAT ONLY COMPONENTS APPROVED BY WALLTHERM AIR® ARE USED FOR THE INSTALLATION AS SUBSTITUTES MAY ADVERSELY AFFECT PERFORMANCE AND MIGHT NULLIFY COMPLIANCE WITH THE REQUIREMENTS OF AS/NZS 2918:2001.
  • Page 8 CORRECT OpERATION OF yOuR WAllTHERm AIR® WOOD FIRE Simply by burning your Walltherm Air® fire correctly, you can improve efficiency, reduce fuel consumption and minimise air pollution. Starting A New Fire Please note: If lighting the fire for the first time, dust fire, glass, trim and flue before firing to avoid particles sticking or discolouring.
  • Page 9 We wait for the flue temperature to reach 50°C to ensure the flue system and the thermal mass of the heater is at the correct temperature to sustain the down draught burning operation. The fire must be left in this mode for the remainder of burn period (excluding re-fuelling only). October 2014 www.jayline.co.nz page 9...
  • Page 10: Important Points To Remember

    This is not a fault or problem and should be ignored unless the ceramics fall apart. Cooking plate and doors: Because of the high temperatures achieved, the colour of the doors and cooking plate will change. October 2014 www.jayline.co.nz page 10...
  • Page 11 It is often necessary to split some of the wood again before using it. The thickest piece size for high-efficiency and use in the Walltherm Air® fire should not exceed about 150mm (6 in.) across the largest dimension, or weigh no more than approximately 1.kg. A range of smaller pieces will be needed for effective starting as described in the lighting instructions.
  • Page 12: Safety Precautions

    WAllTHERm AIR® WOOD FIRE ClEANING The fire requires frequent and thorough cleaning as well as periodical inspection to guarantee it will work properly and ensure constant heat efficiency. When cold use a vacuum cleaner to remove all the ash that has collected in the fire.
  • Page 13 Once done, carefully remove the grid. Clean and vacuum the chamber and parts, then reinstall all items. FIG 6H. FIG 6I. FIG 6J. GRID INJECTOR BLOCK GRID Hole needs to point to the door October 2014 www.jayline.co.nz page 1...
  • Page 14 Clean all tubes with the long brushes! FIG 8C. Important: Every brush must hit the bottom of the lower combustion chamber to make sure every tube is completely cleaned! Repeat until the tubes are free of ash remnants. October 2014 www.jayline.co.nz page 14...
  • Page 15: Cleaning The Glass

    When a flue system becomes excessively blocked or requires frequent cleaning, advice should be sought to investigate the installation and the operation of the fire. Flue pipes can deteriorate very quickly with incorrect firing. October 2014 www.jayline.co.nz page 15...
  • Page 16 CONSumABlES Some parts of your Walltherm Air® fire are considered consumable. They are designed to be replaced as they will degrade over time. The life of the consumables will vary depending on; • How often the fire is used • Type of fuel. Some woods are much harsher than others General items that are considered consumables: •...
  • Page 17 WAllTHERm AIR® – Figs 9 combustion air open closed 20 Volt FIG 9A. FIG 9B. FIG 9C. Upper combustion chamber Upper combustion chamber door with glass Injector block with secondary air feed Upper chamber grid Lower combustion chamber (gas combustion tunnel)
  • Page 18 WARNINGS Below is a list of warnings to ensure efficient and safe operation of your Walltherm Air® wood fire: • WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE. • WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING.
  • Page 19 We select only certain companies to act as our Walltherm Air® dealers. They must have high standards and be able to provide a total service both pre and post sale to you the customer. Therefore we have every confidence that our dealers will be able to answer your questions or fix any problem that may occur.
  • Page 20 WAllTHERm AIR® WOOD FIRE WARRANTy 5 YEARS (conditional) Standard Warranty The Walltherm Air® firebox is warranted for five years, all other components are warranted for twelve months (parts only), provided it has been installed by a suitably qualified installation technician. Conditions The appliance must be installed in accordance with the manufacturers’...
  • Page 21 WAllTHERm AIR® WARRANTy CARD PLEASE COMPLETE AND RETURN WITHIN 0 DAYS OF INSTALLATION TO: RETAIL LINKS LTD PO BOX 9056 ANNESBROOK, 7044 NELSON NAME: ________________________________________________________________________ ADDRESS: ____________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ EMAIL: ________________________________________ PHONE: ________________________ MODEL: ______________________________________________________________________ SERIAL NUMBER: ______________________________________________________________ DATE PURCHASED: ____________________________________________________________...