JAYLINE WALLTHERM AIR Installation & Operation Instructions

Freestanding wood fire

Advertisement

WALLTHERM AIR®
FREESTANDING WOOD FIRE
INSTALLATION & OPERATION INSTRUCTIONS
Please leave this information with the appliance
October 2014
NOVEMBER 2016

Advertisement

Table of Contents
loading

Summary of Contents for JAYLINE WALLTHERM AIR

  • Page 1 WALLTHERM AIR® FREESTANDING WOOD FIRE INSTALLATION & OPERATION INSTRUCTIONS Please leave this information with the appliance October 2014 NOVEMBER 2016...
  • Page 2: Product Registration

    RETAIL LINKS LTD PO BOX 9056 ANNESBROOK, 7044 NELSON NAME: ________________________________________________________________________ ADDRESS: ____________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ EMAIL: ________________________________________ PHONE: ________________________ MODEL: ______________________________________________________________________ SERIAL NUMBER: ______________________________________________________________ DATE PURCHASED: ____________________________________________________________ PURCHASED FROM: ____________________________________________________________ DATE INSTALLED: ______________________________________________________________ INSTALLED BY: ________________________________________________________________ www.jayline.co.nz page 2 NOVEMBER 2016...
  • Page 3 Congratulations on the purchase of your Walltherm Air® Ultra Low Emission Burner, by Jayline. The Walltherm Air® Ultra Low Emission Burner is not a conventional wood fi re, it is a ‘wood gasifi cation stove’, developed for the optimal burning of air dried natural wood.
  • Page 4: Handling And Transport

    INSTALLATION OF YOUR WALLTHERM AIR® ULTRA LOW EMISSION BURNER Walltherm Air® recommends you use a suitably qualifi ed installation technician to install your fi re. Your dealer or heating specialist will be able to help with recommendations as well as advise on permits/consents required for the installation in your area.
  • Page 5 fi xed by gluing when on a concrete fl oor that may have water pipes or electrical wires present. The appliance can then be bolted to the fl oor protector with four 6mm x 50mm dynabolts or equivalent. www.jayline.co.nz page 5...
  • Page 6: Combustion Air

    (hose/pipe & vents not supplied). Attention: Extractor hoods that are installed in the same room as the fi re can cause problems. Attention: If there are other fi replaces near the Walltherm Air® fi re, combustion air must be obtained from outside.
  • Page 7 fi tted with an isolating switch. The electrical installation requires a (COC) Certifi cate of Compliance, obtained from the electrician. Electricity supply 230V / 50Hz FIG 3. WALLTHERM AIR Wire Diagram FAN MOUNTING PLATE TEMPERATURE SENSOR ELECTRICAL ENCLOSURE...
  • Page 8 TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS/NZS 4013:2014 AND/OR CM1. 3. PLEASE ENSURE THAT ONLY COMPONENTS APPROVED BY WALLTHERM AIR® ARE USED FOR THE INSTALLATION AS SUBSTITUTES MAY ADVERSELY AFFECT PERFORMANCE AND MIGHT NULLIFY COMPLIANCE WITH THE REQUIREMENTS OF AS/NZS 2918:2001.
  • Page 9 CORRECT OPERATION OF YOUR WALLTHERM AIR® WOOD FIRE Simply by burning your Walltherm Air® fi re correctly, you can improve effi ciency, reduce fuel consumption and minimise air pollution. Starting A New Fire Please note: If lighting the fi re for the fi rst time, dust fi re, glass, trim and fl ue before fi ring to avoid particles sticking or discolouring.
  • Page 10 fi re. Wait for the fl ue temperature to reach 350°C to ensure the fl ue system and the thermal mass of the heater is at the correct temperature to sustain the down draught burning operation. The fi re must be left in this mode for the remainder of burn period (excluding re-fuelling only). www.jayline.co.nz page 10 NOVEMBER 2016...
  • Page 11: Important Points To Remember

    This is not a fault or problem and should be ignored unless the ceramics fall apart. Cooking plate and doors: Because of the high temperatures achieved, the colour of the doors and cooking plate will change. www.jayline.co.nz page 11 NOVEMBER 2016...
  • Page 12 It is often necessary to split some of the wood again before using it. The thickest piece size for high-effi ciency and use in the Walltherm Air® fi re should not exceed about 150mm (6 in.) across the largest dimension, or weigh no more than approximately 1.3kg. A range of smaller pieces will be needed for effective starting as described in the lighting instructions.
  • Page 13: Safety Precautions

    WALLTHERM AIR® WOOD FIRE CLEANING The fi re requires frequent and thorough cleaning as well as periodical inspection to guarantee it will work properly and ensure constant heat effi ciency. When cold use a vacuum cleaner to remove all the ash that has collected in the fi...
  • Page 14 fi rst. Once done, carefully remove the grid. Clean and vacuum the chamber and parts, then reinstall all items. FIG 6H. FIG 6I. FIG 6J. GRID INJECTOR BLOCK GRID Hole needs to point to the door www.jayline.co.nz page 14 NOVEMBER 2016...
  • Page 15 Clean all tubes with the long brushes! FIG 8C. Important: Every brush must hit the bottom of the lower combustion chamber to make sure every tube is completely cleaned! Repeat until the tubes are free of ash remnants. www.jayline.co.nz page 15 NOVEMBER 2016...
  • Page 16: Cleaning The Glass

    When a fl ue system becomes excessively blocked or requires frequent cleaning, advice should be sought to investigate the installation and the operation of the fi re. Flue pipes can deteriorate very quickly with incorrect fi ring. www.jayline.co.nz page 16 NOVEMBER 2016...
  • Page 17 CONSUMABLES Some parts of your Walltherm Air® fi re are considered consumable. They are designed to be replaced as they will degrade over time. The life of the consumables will vary depending on; • How often the fi re is used •...
  • Page 18 WALLTHERM AIR® – Figs 9 FIG 9A. FIG 9B. FIG 9C. Upper combustion chamber Upper combustion chamber door with glass Injector block with secondary air feed Upper chamber grid Lower combustion chamber (gas combustion tunnel) Lower combustion chamber door with glass...
  • Page 19 WARNINGS Below is a list of warnings to ensure effi cient and safe operation of your Walltherm Air® wood fi re: • WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE. • WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING.
  • Page 20 fi re. We select only certain companies to act as our Walltherm Air® dealers. They must have high standards and be able to provide a total service both pre and post sale to you the customer. Therefore we have every confi...
  • Page 21 All claims (in the rst instance) should be directed to the store of purchase. Any repairs undertaken without the manufacturer’s authority will render the guarantee void. Water boosters must be a Jayline model speci ed with the re to be covered; this guarantee applies to the original purchaser only.
  • Page 22 22 NOVEMBER 2016...

Table of Contents