4 GENERAL TECHNICAL DATA

VOLUME
RATED PRESSURE
ELECTRIC CONNECTION
RECOMMENDED BREAKER
INPUT
EL. PROTECTION
MAX. WEIGHT OF THE HEATER
WITHOUT WATER (WITH WATER)
TIME OF EL. HEATING FROM 10 °C
TO 60 °C
MIXED WATER V40
LOAD PROFILE
ENERGY EFFICIENCY CLASS
ENERGY EFFICIENCY
ANNUAL CONSUMPTION OF ELECTRIC
ENERGY

5 OPERATING ACTIVITY

After connecting the heater to the mains, the immersion heater heats up the water. The element is turned
on and off by a thermostat. After reaching the temperature set, the thermostat switches off the electrical
circuit and discontinues water heating. The heat control light signals if the element is in operation (the light
is on) or if it is off (the light goes out).

6 WALL MOUNTING

Prior to mounting check the loading capacity of the wall. If needed, reinforce it. Mount the water heater
in vertical position only. The fastening screws must have guaranteed spacing of 140 mm. The mounting
dimensions are specified in Fig. 3.
TO 5.1 IN/UP
l
4.6
bar
6
W
kg
6.0 (10.6)
min
13
l
4.06 / 5.51
XXS
A
%
36.24 / 37.10
kWh
509 / 497
Table 1
TO 10.1 IN/UP
9.6
6
1 PE-N 230V/50HZ
16 A
1500
IP X5
8.0 (17.6)
25
11.2 / 13.38
XXS
A
35.17 / 35.12
525
- 5 -