3B. Module Replacement-Serial Number
216B and Newer
Complete the following to reinstall the refrigerator
module:
1. Ensure that the control wiring runs through the
channel in the refrigerator body.
Note
Two thick, black cables connect the power supply with
the AC and compressor (Figure 15). Ensure that
cables are side by side and not crossed during
reassembly.
Figure 15: Rear view with the module removed
2. Slide the refrigeration module to the rear of the
refrigerator and place the drain tube in the drip
pan on the module (Figure 16).
Figure 16: Position drain tube in front half of the drip
pan
3. Ensure the black gasket is aligned and gasket
nubs are inserted in corresponding holes on the
frame of the refrigerator module (Figure 17).
Figure 17: Position gasket on refrigeration module
frame and ensure each gasket nub is inserted in
corresponding hole
When reinstalling the refrigeration module, do not pinch
the sensor wiring.
4. Install the module, tipping the top back while
sliding the bottom forward. When the bottom of
the system is in place, push the top into place
(Figure ). Ensure the slack in the power cord is
removed before securing refrigeration module
frame.
Figure 18: Slide module into place
When reinstalling all self-tapping screws, avoid
destroying the plastic threads. First seat each screw in
its hole and, without pressing down, rotate the screw
counter-clockwise until it falls into its thread groove with
a "click. " Then tighten the screw.
5. Reinstall the coil shield, back cover, and insula-
tion panel (Figure 19). When installing the foam
insulation panel, take precautions not to damage
the foam around the tubing (see inset Figure 19).
6
Gasket
Nub
CAUTION
Push top in
second.
Push bottom
in first.
CAUTION

Advertisement