Download Print this page

Teledyne 5800 Instruction Sheet page 4

Refrigerator compressor capacitor/relay kit

Advertisement

60-4702-009 Revision D, June11, 2020
blue
black
white connector
(orange on left)
Figure 7: 230 VAC new wiring connections
Figure 8: 230 VAC route and secure wires
(side view of compressor terminals)
12.
Route all wire connections inside the compressor
terminal box and replace the cover.
Note
If you have a unit with serial number 216B or greater,
skip to section 3B. Module Replacement-Serial
Number 216B and Newer.
3A. Module Replacement - Serial
Number 216B and Older
The refrigeration module and rear compartment of
the cabinet have adhesive strips and Permagum
(caulking cord sealant) protecting the components
(Figures 9 and 10). Ensure that all adhesive strips and
Permagum are still in place before reassembly.
The adhesive strips and Permagum are required to
1. Permagum is a registered trademark of the Presstite Engineering Company.
blue
ribbed
black
Top Slot Wires:
• ribbed and smooth
fan wires
Middle Slot Wires:
• single blue
• orange
• black (x2)
• single green/yellow
1
prevent air flow between the condenser coil and the
evaporator plate. Without this protection, water con-
densation on the coil will cause ice build-up, resulting in
poor refrigerator performance.
Note
Two thick, black cables connect the power supply with
the AC and compressor (see Figure 9). Ensure that
these cables are side by side and not crossed
during reassembly.
Permagum
sealant
Power supply cables
Figure 9: Rear view with module removed
(Adhesive strips, Permagum sealant, power cables)
Adhesive
strip
Permagum
sealant
Figure 10: Rear view of refrigeration module
(Adhesive strip, Permagum sealant)
1. Move the refrigeration module up to the rear of
the refrigerator and replace the drain tube in
the drip pan on the module.
4
Adhesive strips
Center
screw

Advertisement