Distance To The Pool; Connecting The By-Pass - COMFORTPOOL PRO+5 Installation Instructions Manual

Swimming pool heat pump unit
Table of Contents

Advertisement

Available languages

Available languages

The picture below illustrates the minimum required distances from each side of the heat pump.

3.2 Distance to the pool

Install the heat pump as close to the swimming pool as possible to minimize heat loss through the piping.
Normally, the pool heat pump is installed within a 7.5-meter radius of the pool. The greater the distance
from the pool, the greater the heat loss from the piping. If the piping is buried, heat loss will be minimal for
distances of up to 30 meters (15 meters to and from the pump = 30 meters total), unless the soil is wet or
the water level is high. Heat loss per 30 meters can be roughly be estimated at 0.6kw-hour (2000 BTU) for
every 5 ℃ temperature difference between the pool water and the soil surrounding the pipe, which
translates to an operation time increase of 3-5%.

3.3 Connecting the by-pass

VALVE1 – Slightly closed
(water pressure increased from 10 to 20 bar)
VALVE2 – Completely open
VALVE3 – Half way open
Setting the valve of the by-pass:
1. Open all 3 valves entirely
2. Slightly close valve 1
3. Close valve 3 about half way to adjust the
refrigerant pressure
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro+7Pro+10Pro+13Pro+18Pro+24

Table of Contents