loading

Summary of Contents for COMFORTPOOL PRO+5

  • Page 1 SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual ZWEMBAD WARMTEPOMP Installatie & Gebruikershandleiding Applicable Model / Van toepassing op: PRO+5 PRO+7 PRO+10 PRO+13 PRO+18...
  • Page 2: Table Of Contents

    Contents 1. PREFACE ____________________________________________________________________________ 4 2. SPECIFICATIONS _______________________________________________________________________ 6 2.1 Parameters of Swimming Pool Heat Pump Unit _______________________________________________________________ 6 2.2 Dimensions of swimming pool heat pump unit _______________________________________________________________ 7 3. INSTALLATION ________________________________________________________________________ 8 3.1 Heat pump location _____________________________________________________________________________________ 8 3.2 Distance to the pool ____________________________________________________________________________________ 9 3.3 Connecting the by-pass __________________________________________________________________________________ 9 3.4 Electrical wiring _______________________________________________________________________________________ 10 3.5 Initial start-up ________________________________________________________________________________________ 10...
  • Page 3 Inhoud 1. INLEIDING __________________________________________________________________________ 23 2. SPECIFICATIES _______________________________________________________________________ 25 2.1 Technische gegevens van de zwembad warmtepomp _________________________________________________________ 25 2.2 Afmetingen van de zwembad warmtepomp ________________________________________________________________ 26 INSTALLATIE _______________________________________________________________________ 27 3.1 Locatie van de warmtepomp _____________________________________________________________________________ 27 3.2 Afstand tot het zwembad _______________________________________________________________________________ 28 3.3 Aansluiting van de bypass _______________________________________________________________________________ 28 3.5 Elektrische bedrading __________________________________________________________________________________ 29 3.6 Eerste gebruik ________________________________________________________________________________________ 29...
  • Page 4: Preface

    SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual 1. Preface In order to provide our customers with quality, reliability and versatility, this product has been made to strict producing standards. This manual includes all necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit.
  • Page 5 Safety warnings & instructions Read and follow all instructions in this manual and on the equipment. Failure to do so could result in severe or fatal injuries, or damage the heat pump. The heat pump should be installed in accordance with local regulations, and the requirements in this manual. This is not a TOY.
  • Page 6: Specifications

    2. Specifications 2.1 Parameters of Swimming Pool Heat Pump Unit MODEL PRO+5 PRO+7 PRO+10 PRO+13 PRO+18 PRO+24 Heating Capacity in 4300 6100 8900 11500 13700 15500 A27/W27°C Heating Capacity in 3000 4500 6500 8000 9200 11000 A15/W26°C Heating Capacity 3800...
  • Page 7: Dimensions Of Swimming Pool Heat Pump Unit

    2.2 Dimensions of swimming pool heat pump unit PRO+ 5 PRO+ 13 PRO+ 18 Model PRO+ 7 PRO+ 10 Size (mm) 1010 1100...
  • Page 8: Installation

    3. Installation The factory only provides the heat pump unit. Other items, including an eventual bypass, that are necessary for the water system, are to be provided by users or installers. Attention! Please follow these steps when installing the heat pump: 1.
  • Page 9: Distance To The Pool

    The picture below illustrates the minimum required distances from each side of the heat pump. 3.2 Distance to the pool Install the heat pump as close to the swimming pool as possible to minimize heat loss through the piping. Normally, the pool heat pump is installed within a 7.5-meter radius of the pool. The greater the distance from the pool, the greater the heat loss from the piping.
  • Page 10: Electrical Wiring

    3.4 Electrical wiring Note: Verify the local power supply and the operating voltage of the heat pump. It is recommended to use the included separate circuit breaker for the heat pump, together with the proper wiring characteristics (see wiring diagram). The current to the heat pump should only be applied when the filter pump is running. Further connect the electrical supply to the junction box inside the unit.
  • Page 11: Condensation

    3.6 Condensation When the swimming pool water is being heated by the heat pump, the incoming air is cooled down quite a bit, which can cause condensation on the fins of the evaporator. Condensed volumes can attain several liters per hour under high atmospheric humidity. Sometimes, this is wrongfully interpreted as a water leak. 4.
  • Page 12: Spring Start-Up

    4.3 Spring start-up If your heat pump has been winterized, perform the following steps when starting the system in the spring: 1. Inspect the system for any debris or structural problems. 2. Connect the water inlet and outlet couplers firmly. 3.
  • Page 13: Lcd Controller Display

    5. LCD Controller Display 5.1 Setting step 1. Under running status, press  to adjust the temperature. 2. Press “Mode” to choose the mode: 3. Press “Mode” again cooling 4. Press “Mode” again heating 5. Standby status: Warning! These default settings are correctly preset. Only allow a qualified heat pump technician to change them. - Press “Mode”...
  • Page 14: The Functions Of Controller Display

    - Press “Mode” again “E” “40”. Press “SET” to enter Max. temp. setting. Press  to alter. Press “SET” again to confirm. - Press “Mode” again “F” “2”. Press “SET” to enter Split temp. setting. Press  to alter. Press “SET” again to confirm.
  • Page 16 To choose Mode How to check the current status Ambient temp. Under running status, press “Mode” for 5 seconds to check the current status of the unit! You can check water-in/water-out temp, condenser temp and ambient temp. Note: If no motion is detected on the display for 10s, the LCD will display water-in/water-out temp (under running) or ambient temp.
  • Page 17: Operation Data Setting Table

    5.3 Operation data setting table: DIGIT MEANING RANGE DEFAULT ADJUST (YES/NO) Return water temp. setting (cooling 8°C – 28°C 27°C mode) Return water temp. setting (heating 15°C – 40°C 27°C mode) Total working time of compressor after To be adjusted by 30 –...
  • Page 18: Maintenance And Inspection

    6. Maintenance and Inspection 6.1 Maintenance • Check the water supply device and the releaser often. There should always be water entering the system. The condition air entering the system should be avoided, or it will influence unit's performance and reliability. You should clear the water filter regularly to avoid damage to the unit because of a jammed filter.
  • Page 19 The first time freezing PP 07 Ambient temp. too low protection in winter The second time freezing protection in PP 07 Ambient temp. too low winter Coil sensor failure The sensor is open or short PP 08 Check or change the sensor (Cooling mode) circuit Refrigerant system pressure...
  • Page 20: Wiring Diagram

    7. Wiring diagram Model: PRO+5 PRO+7 PRO+10 PRO+13...
  • Page 21 Model: PRO+ 18 PRO+ 24...
  • Page 22: Warranty

    This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have been moved from their original installation sites. The liability of Comfortpool shall not exceed the repair of replacement of defective parts and does not include any costs for labor to remove and reinstall a defective part, transportation to or from the factory or supplier, and any other materials required to execute a possible repair.
  • Page 23: Inleiding

    ZWEMBAD WARMTEPOMP Installatie & Gebruikershandleiding 1. Inleiding Teneinde kwaliteit, betrouwbaarheid en veelzijdigheid aan onze klanten te kunnen leveren voldoet dit product aan strenge productienormen. Deze handleiding beval alle benodigde informatie ten aanzien van de installatie, probleemoplossing, het laten leeglopen en het onderhoud van de warmtepomp.
  • Page 24 Veiligheidsvoorschriften Lees en volg alle instructies in deze handleiding en op het apparaat. Het niet in acht nemen van deze instructies kan leiden tot ernstige of dodelijke verwondingen, of de warmtepomp beschadigen. Installatie van de warmtepomp dient te geschieden conform de ter plaatse geldende voorschriften, en de voorschriften in deze handleiding.
  • Page 25: Specificaties

    2. Specificaties 2.1 Technische gegevens van de zwembad warmtepomp MODEL PRO+5 PRO+7 PRO+10 PRO+13 PRO+18 PRO+24 Verwarmingscapaciteit in 4300 6100 8900 11500 13700 15500 A27/W27°C Verwarmingscapaciteit in 3000 4500 6500 8000 9200 11000 A15/W26°C Verwarmingscapaciteit 3800 5300 7800 9500 12500...
  • Page 26: Afmetingen Van De Zwembad Warmtepomp

    2.2 Afmetingen van de zwembad warmtepomp PRO+ 5 PRO+ 13 PRO+ 18 Model PRO+ 7 PRO+ 10 Maat (mm) 1010 1100...
  • Page 27: Installatie

    3. Installatie De fabriek levert alleen de warmtepomp; andere noodzakelijke onderdelen voor het watersysteem, waaronder een mogelijke bypass, dienen door de installateur of gebruiker te worden aangeschaft. Let op! Voer onderstaande stappen uit bij het installeren van de warmtepomp: 1. Chemicaliën dienen stroomafwaarts van de warmtepomp aan het zwembadwater te worden toegevoegd.
  • Page 28: Afstand Tot Het Zwembad

    Onderstaande afbeelding geeft de minimaal vereiste vrije ruimte aan elke zijde van de warmtepomp weer. 3.2 Afstand tot het zwembad Installeer de warmtepomp zo dicht mogelijk bij het zwembad om warmteverlies via de leidingen te beperken. Normaal gesproken wordt de warmtepomp binnen een straal van 7,5 meter van het zwembad geïnstalleerd.
  • Page 29: Elektrische Bedrading

    3.4 Elektrische bedrading Let op: Controleer de lokale stroomvoorziening en de nodige ingangsspanning van de warmtepomp. Het is aan te raden de meegeleverde aparte beveiligingsautomaat voor de warmtepomp te gebruiken, in combinatie met de juiste bedrading (zie bedradingsschema). Er mag alleen stroom naar de warmtepomp lopen wanneer de filterpomp aanstaat.
  • Page 30: Condensatie

    3.6 Condensatie Wanneer het zwembadwater met de warmtepomp wordt verwarmt wordt de ingaande lucht een beetje gekoeld, wat condensatie op de lamellen van de verdamper kan veroorzaken. De hoeveelheid condens kan bij een hoge luchtvochtigheid wel oplopen tot meerdere liters per uur. Dit wordt soms ten onrechte aangezien voor een waterlekkage.
  • Page 31: Voorjaarsopstart

    4.3 Voorjaarsopstart Heeft u de warmtepomp winterklaar gemaakt, volg dan de volgende stappen om het systeem in de lente op te starten: 1. Inspecteer het systeem op vuil of structurele problemen. 2. Sluit de koppelstukken voor de watertoevoer en -uitlaat stevig aan. 3.
  • Page 32: Lcd Controller Display

    5. LCD Controller Display 5.1 Instellen Onder “Running status”, druk op  om de temperatuur aan te passen. 2. Druk op “Mode” om de modus te selecteren. 3. Druk nogmaals op “Mode” koelen 4. Druk nogmaals op “Mode” verwarmen 5. Stand-by status Let op! Deze instellingen staan standaard goed ingesteld! Laat dit alleen wijzigen door een gekwalificeerde warmtepomptechnicus.
  • Page 33 - Druk nogmaals op “Mode”. “D” “5”. Druk op “SET” voor overhittingsbescherming (koelingsmodus). Druk op  om te wijzigen. Druk op “SET” om te bevestigen. - Druk nogmaals op “Mode”. “E” “40”. Druk op “SET” voor instellen max. temperatuur. Druk op  om te wijzigen. Druk op “SET”...
  • Page 34: De Functies Van Het Bedieningsdisplay

    5.2 De functies van het bedieningsdisplay Instellen van de gebruiksparameters Onder “Stand-by status”, druk 5 seconden op “Mode” om naar de Operation Parameter Setting te gaan; Druk nogmaals op “Mode” om te beginnen met instellen (parameter van 00-D, zie de tabel gebruiksinstellingen);...
  • Page 36 Modus kiezen 1. Druk op “Mode” om modus te kiezen (modus kan gewijzigd worden onder “running”) 2. Onder “running” geeft het display de water-in en water-uit temperatuur weer, en de huidige status. 3. Auxiliaire elektrische verwarming alleen voor apparaten met deze functie (niet aanwezig op de Pro+ warmtepompen) Hoe de huidige status af te lezen Onder “running status”, druk 5 seconden op “Mode”...
  • Page 37: Tabel Gebruiksinstellingen

    5.3 Tabel gebruiksinstellingen: CIJFER BETEKENIS BEREIK STANDAARD AANPASSEN (JA/NEE) Retourwatertemperatuur instelling 8°C – 28°C 27°C (koelingsmodus) Retourwatertemperatuur instelling 15°C – 40°C 27°C (verwarmingsmodus) Totale werkingstijd van compressor Aan te passen door 30 – 90 min 40 min na vorst. technicus Instelling begintemperatuur voor Aan te passen door -30°C –...
  • Page 38: Onderhoud And Inspectie

    6. Onderhoud and inspectie 6.1 Onderhoud • Controleer regelmatig de watertoevoer en -uitlaat. Er moet altijd water door het systeem lopen. Lucht in het systeem moet voorkomen worden, dit kan de prestaties en de betrouwbaarheid van het apparaat beïnvloeden. Maak de waterfilter regelmatig schoon om te voorkomen dat het apparaat beschadigd door een verstopte filter.
  • Page 39 Eerste maal Te lage bevriezingsbescherming PP 07 omgevingstemperatuur in de winter Tweede maal Te lage bevriezingsbescherming PP 07 omgevingstemperatuur in de winter Spoelsensor storing De sensor is open of PP 08 Controleer of vervang de sensor (koelingsmodus) kortsluiting Controleer de drukmeter of voeg Hoge druk bescherming EE 01 Druk in koelsysteem is hoog.
  • Page 40: Bedradingsdiagram

    7. Bedradingsdiagram Model: PRO+ 5 PRO+ 7 PRO+ 10 PRO+ 13...
  • Page 41 Model: PRO+ 18 PRO+ 24...
  • Page 42: Garantie

    De aansprakelijkheid van Comfortpool zal nooit de reparatie of vervanging van defecte onderdelen te boven gaan, en zal geen kosten omvatten voor arbeid om een defect onderdeel te verwijderen en opnieuw te installeren, noch het transport van en naar de fabriek of leverancier, noch enig ander materiaal dat nodig is voor het uitvoeren van een eventuele reparatie.

This manual is also suitable for:

Pro+7Pro+10Pro+13Pro+18Pro+24

Table of Contents