Brave BRM500 Operation And Service Manual page 13

Table of Contents

Advertisement

BRAVE
Copper Wire
Size Minimum
AWG
16
15
14
12
10
8
6
4
2
Based on Ambient Temperature of 86˚F (30˚C)
Based on no more than 100 feet
* Use AMP Draw indicated the same or higher than your machine output.
EXAMPLE: Machine AMP Draw 51, use 55 (2 Conductor): The thermostat type of cord
shall be C, PD, E, EO, EN, S, So, SRD, SJ, SJO, SV, SVO, SP.
The thermo set plastic types shall be ET, ETT, ETLB, ETP, ST, STO, SRDT, SJT, SJTO,
SVT, SVTO, and SPT.
Water Supply
This machine must have a water supply capable of flushing the machine after use. The water supply
must be at least 2 Gallon / 7.5 Liter to 5 gallon/ 18.9 Liter and a minimum water inlet pressure of 10
PSI/ 0.68 BAR.
Barrier
We recommend a barrier be installed between the machine and wash area to prevent moisture from
coming in direct contact with electrical controls, motors and transformers. This will increase the
machine's life and lessen electrical problems.
Water Conditions
Local water conditions affect the pressure washer components adversely more than any other
element. In areas where troublesome conditions may exist with like equipment (such as water
heaters), we recommend the use of a water softener.
Freezing
This machine must be protected from freezing according to storage section of MACHINE
MAINTENANCE.
Specifications
10
Machine
AMP Draw*
3 Conductor
2 Conductor
Wires
10
--
15
20
25
35
45
60
80
800-350-8739
Machine
AMP Draw*
Wires
13
--
18
25
30
40
55
70
95
www.braveproducts.com

Advertisement

Table of Contents
loading

Table of Contents