Vulcan-Hart MHB24E Service Manual page 35

Vhx boiler base series high efficiency electric steamer
Hide thumbs Also See for MHB24E:
Table of Contents

Advertisement

1)
Compartment steam solenoid valve
energized and steam begins to enter
the compartment.
2)
Ready light (green) goes out and
Cooking light (red) comes on.
NOTE: Steam should not be seen entering
either compartment until a cook time is set.
This energizes the steam solenoid valve of
the cooking compartment to allow steam
flow.
4.
Time expires on timer.
A.
Timer contacts 1/3 open, timer motor de-
energized.
B.
Steam solenoid valve de-energizes,
stopping the flow steam into compartment.
C.
Timer contacts 4/1 close and energize
buzzer until manually turned off.
D.
Cooking light (red) goes out and Ready
light (green) comes on.
5.
Timer manually turned off.
A.
Contacts 1/4 open.
B.
Alarm Buzzer de-energized and stops
buzzing.
6.
Steamer reverts to preheat cycle until time is
dialed on timer and the door is shut, water level
drops below low level cut-off probe or the power
switch is turned off.
VHX SERIES STEAMER - ELECTRICAL OPERATION
Page 35 of 48
F25154 (February 2004)