Graco Viscount II Instructions-Parts List Manual page 29

4-ball pumps
Hide thumbs Also See for Viscount II:
Table of Contents

Advertisement

See Models on page 3 for your pump part number.
Key:
A
10.3 MPa, 103 bar (1500 psi) hydraulic pressure
B
7.2 MPa, 72.4 bar (1050 psi) hydraulic pressure
C
4.1 MPa, 41 bar (600 psi) hydraulic pressure
NOTE: The shaded area within the table shows the
recommended range for continuous duty circulation
applications.
Fluid Outlet Pressure
psi
MPa, bar
10
400
2.8, 28
A
300
2.1, 21
B
200
1.4, 14
C
100
0.7, 7
0
gpm
0
8
liters/minute
30
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
Fluid Outlet Pressure
psi
MPa, bar
8
2.1, 21
A
1.8, 17.5
B
1.4, 14
1.0, 10
C
0.7, 7
0.35, 3.5
gpm
liters/minute
30
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
3A0537G
Viscount II Motor, 3000cc Lower
cycles per minute
21
31
42
52
16
24
32
40
60
91
121
151
Viscount II Motor, 4000cc Lower
cycles per minute
15
23
30
38
46
60
91
121
151
181
gpm
l/min
60
12
45
10
38
8
30
6
23
4
15
2
7.6
0
48
gpm
0
181
liters/minute
gpm
l/min.
53
60
45
30
15
gpm
liters/minute
212
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
Performance Charts
Hydraulic Oil Consumption
cycles per minute
10
21
31
42
8
16
24
32
30
60
91
121
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
Hydraulic Oil Consumption
cycles per minute
8
15
23
30
30
60
91
121
151
52
60
40
48
151
181
38
46
53
181
212
29

Advertisement

Table of Contents
loading

Table of Contents