1-3. Specifications

Instrument specifications are presented in Table 1-1.
Function
Range
F
3.200 V
32.00 V
320.0 V
1000 V
l
320.0 mV
320.00
3.200 k
J
32.00 k
320.0 k
(nS)
3.200 M
32.00 M
32.00 nS
ML
2.080 V
G
3.200 V
32.00 V
320.0 V
1000 V
I
320.0 mV
* When using the REL ∆ function to compensate for offsets.
Function
Range
N
32.00 mA
A
m
/
320.0 mA
10.00 A
c
320.0 µA
µA
3200 µA
d
32.00 mA
mA/A
320.0 mA
10.00 A
40-1000 Hz
d
320.0 µA
µA
3200 µA
40-1000 Hz
Table 1-1. Specifications
Resolution
0.001 V
0.01 V
0.1 V
1 V
0.1 mV
J
J
0.1
J
J
0.001 k
J
J
0.01 k
J
J
0.1 k
J
J
0.001 M
J
J
0.01 M
0.01 nS
0.001 V
0.001 V
0.01 V
0.1 V
1 V
0.1 mV
Resolution
0.01 mA
0.1 mA
0.01 A
0.1 µA
1 µA
0.01 mA
0.1 mA
0.01 A
0.1 µA
1 µA
Introduction and Specifications
Accuracy
±(0.1%+1)
±(0.1%+1)
±(0.1%+1)
±(0.1%+1)
±(0.1%+1)
±(0.3%+3)*
±(0.2%+1)
±(0.2%+1)
±(0.2%+1)
±(0.2%+1)
±(1%+1)
±(0.2%+10)
±(1%+1) typical
40 Hz-2 kHz
2 kHz -10 kHz
±(0.5%+3)
±(2%+3)
±(0.5%+3)
±(2%+3)
±(0.5%+3)
±(2%+3)
±(1%+3)
±(3%+3)
±(0.5% +3)
±(2%+3)
Accuracy
Typical Burden Voltage
±(0.75%+2)
5.6 mV/mA
±(0.75%+2)
5.6 mV/mA
±(0.75%+2)
50 mV/A
±(0.75%+2)
0.5 mV/µA
±(0.75%+2)
0.5 mV/µA
±(1.5%+2)
5.6 mV/mA
±(1.5%+2)
5.6 mV/mA
±(1.5%+2)
50 mV/A
±(1.5%+2)
0.5 mV/µA
±(1.5%+2)
0.5 mV/µA
1
Specifications
10 kHz -30 kHz
±(4%+ 10)
±(4%+ 10)
±(4%+ 10)
Not Specified
±(4%+10)
1-5