7.16
Replacing the level electrode for the carbonator tank
Prerequisites
The cover has been removed.
Spare parts
Energize 3 (R134a): Level electrode
Energize 4 (R134a): Level electrode
Energize 5 (R134a) single: Level electrode
Energize 5 (R134a) dual: Level electrode
Seal
1. Disconnect the plug (Fig. 74/1) from the level electrode (Fig. 74/2).
2. Disconnect the earth cable (Fig. 74/3).
3. Turn the level electrode (Fig. 75/1) and remove it from the carbonator tank (Fig. 75/2).
4. Check the seal (Fig. 76/1) of the level electrode (Fig. 76/2) for damage.
Replace any damaged seals (Fig. 76/1).
5. Attach the new level electrode (Fig. 75/1) to the carbonator tank (Fig. 75/2) by turning it.
6. Connect the earth cable (Fig. 74/3).
7. Connect the plug (Fig. 74/1) of the level electrode (Fig. 74/2).
Finishing tasks
1. Mount the cover; see chapter 7.1.