Replacing The Non-Return Valve Of The Solenoid Valve For The Carbonator Tank - Cornelius Energize Series Installation And Service Manual

Undercounter cooler
Hide thumbs Also See for Energize Series:
Table of Contents

Advertisement

7.14

Replacing the non-return valve of the solenoid valve for the carbonator tank

Prerequisites
The solenoid valve for the carbonator tank has been removed.
Spare parts
Energize 3 (R134a): Non-return valve
Energize 4 (R134a): Non-return valve
Energize 5 (R134a) single: Non-return valve
Energize 5 (R134a) dual: Non-return valve
Seal
Thread adhesive
1. Disconnect the non-return valve (Fig. 68/2) from the solenoid valve (Fig. 68/1).
2. Apply Loctite to the new non-return valve (Fig. 68/2).
3. Attach the non-return valve (Fig. 68/2) to the solenoid valve (Fig. 68/1).
4. Check the seals (Fig. 69/2) for damage.
Replace any damaged seals (Fig. 69/2).
Finishing tasks
1. Mount the solenoid valve for the carbonator tank; see chapter 7.13.
Cornelius Deutschland GmbH
Document no. TD1005100
Version 08/10/2019, Index 3
References
see chapter 7.13
ID/reference
220105624
220105624
220105624
220105624
311304000
Loctite 243
Qty/amount
Comment
1
1
1
1
1
Plastic, black 5/8"
1
Fig. 68
1
Fig. 69
Installation and service manual Undercounter cooler
Energize 3-5 (R134a)
Repairs
2
2
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Energize 3Energize 5Energize 4

Table of Contents