Valve Adjustment; Instruction Manual C886G | C887G | C889G; Please Keep This Instruction Manual For Future Reference - Caple C886G Instruction Manual

Gas-on-glass gunmental hob
Hide thumbs Also See for C886G:
Table of Contents

Advertisement

R E P L A C E M E N T O F B U R N E R I N J E C TO R
- Loosen the injector with a dedicated wrench (7). Fit the new injector, suitable for the required
gas type (see table above for reference)
- After you have converted the hob to another gas type, make sure you have placed a label
containing that information on the appliance.
- Adjustment of the reduced valve flow
Replacement of burner injector: Loosen the injector with a dedicated
wrench(7).Fit the new injector, suitable for the required gas type (see table above for reference)。
After you have converted the cooktop to another gas type, make sure you have placed a label
containing that information on the appliance.
Adjustment of the reduced valve flow
Table2
Burners
Flame
Full flame
Regular burners
Saving flame

Valve adjustment

Valve adjustment should be done with the control knob set at Burner ON saving flame position.
Remove the knob, and adjust the flame with a small screwdriver (see fig.7 below).
Fig.7
Checking the adjusted flame: heat the burner at full open position for 10 minutes. Then turn the knob into the
minimum setting. The flame should not extinguish nor move to the injector. If it goes off or moves over to the
injector, readjust the valves.
Note.
It is up to the user to request converting the appliance to another gas type if so required by the local conditions at a
licensed gas fitter/ service.
20

Instruction manual C886G | C887G | C889G

Converting the
Converting the
cooktop from LPG
Cooktop from natural
to natural gas
Gas to LPG
Replace the burner
Replace the burner
Injector according
injector according
To the guidelines in
to the guidelines in
table 1
table 1
Loosen the adjustment
Loosen the adjustment
Spindle (see fig.7 below )
Spindle (see fig.7 below )
And adjust the flame
And adjust the flame

Please keep this instruction manual for future reference

Full flame
Regular burners
VA LV E A D J U S T M E N T
Regular burners
Saving flame
Valve adjustment should be done with the control knob set at Burner ON saving flame position.
Remove the knob, and adjust the flame with a small screwdriver (see fig.7 below).
Checking the adjusted flame: heat the burner at full open position for 10 minutes. Then turn the
knob into the minimum setting. The flame should not extinguish nor move to the injector. If it goes
Valve adjustment
Valve adjustment
off or moves over to the injector, readjust the valves.
Valve adjustment should be done with the control knob set at Burner ON saving flame po
Valve adjustment should be done with the control knob set at Burner ON saving flame position.
F I G. 7
Remove the knob, and adjust the flame with a small screwdriver (see fig.7 below).
Remove the knob, and adjust the flame with a small screwdriver (see fig.7 below).
Fig.7
Fig.7
N OT E :
It is up to the user to request converting the appliance to another gas type if so required by the
Checking the adjusted flame: heat the burner at full open position for 10 minutes. Then turn the
Checking the adjusted flame: heat the burner at full open position for 10 minutes. T
local conditions at a licensed gas fitter/service.
minimum setting. The flame should not extinguish nor move to the injector. If it goes off or mo
minimum setting. The flame should not extinguish nor move to the injector. If it goe
injector, readjust the valves.
injector, readjust the valves.
Note.
Note.
It is up to the user to request converting the appliance to another gas type if so required by the local
It is up to the user to request converting the appliance to another gas type if so required
licensed gas fitter/ service.
licensed gas fitter/ service.
Please keep this instruction manual for future reference
to natural gas
Full flame
Replace the burner
Replace the burner
Injector according
Injector according
To the guidelines in
To the guidelines in
table 1
table 1
Saving flame
Loosen the adjustment
Loosen the adjustment
Spindle (see fig.7 below )
Spindle (see fig.7 below )
And adjust the flame
And adjust the flame
Instruction manual C886G | C887G | C889G
Gas to LPG
Replace th
injector acc
to the guide
table 1
Loosen the
Spindle (se
And adjust
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

C887gC889g

Table of Contents