Section 5 - Troubleshooting; Symptom / Resolution Charts; Control Panel Not Working; Heat Pump Not Running - Aquacal AutoPilot WS03 Operation And Installation Manual

Water source
Hide thumbs Also See for AutoPilot WS03:
Table of Contents

Advertisement

Page 32
When ready to heat the spa, select the "SPA" thermostat to heat the spa to the desired temperature. This
will result in reduced warm up periods over full cold starts. Switch back to the "POOL" thermostat when
done using the spa.
To prevent excessive heat loss and increased run time, use a spa cover and turn off air blowers when
heating spas.

SECTION 5 - TROUBLESHOOTING

5.1 Symptom / Resolution Charts

WARNING
- Failure to heed the following may result in injury or death.
WARNING
- Failure to heed the following may result in injury or death.
CAUTION
- Failure to heed the following may result in equipment damage.
Please note – Troubleshooting charts are for Main Controller version 3.0.
SYMPTOM

Control Panel Not Working

Heat Pump Not Running

Repairs must not be attempted by untrained unqualified individuals. If service is
deemed necessary, contact installing dealer or AquaCal AutoPilot Customer
Support.
Heat pump contains refrigerant under high pressure. Repairs to refrigerant circuit
must not be attempted by untrained or unqualified individuals. Service must be
performed only by qualified HVAC technicians. Recover refrigerant before opening
system.
Service by un-authorized personnel will void factory warranty.
RULE OUT
An external
controller is
being used
No power to heat
pump
Incorrect mode
setting
Thermostat set
incorrectly
Error displayed
RESOLUTION
STEP 1:
See section entitled "Configuring for External Controller"
on page 29 for more information on heat pump
controller functionality when using external controllers.
STEP 2:
Call heat pump installer or AquaCal AutoPilot Customer
Support for further assistance.
STEP 1:
Confirm heat pump display is illuminated.
 If not, confirm the main breaker (located at the
power supply panel) and the disconnect switch
(located near the heat pump) are both turned ON.
 If yes, proceed to next step.
STEP 2:
Confirm correct mode is selected. See "Setting
Operating Mode" on page 3. If heat pump still does not
turn on, proceed to next step.
STEP 3:
Confirm that thermostat is set above / below current
water temperature depending on mode setting. See
"Setting Thermostats" on page 3. If heat pump still does
not turn on, proceed to next step.
STEP 5:
If an error code is displayed, see appropriate fault code
in this section. If no fault code is displayed, proceed to
next step.