Planned Maintenance - Aquacal AutoPilot WS03 Operation And Installation Manual

Water source
Hide thumbs Also See for AutoPilot WS03:
Table of Contents

Advertisement

Page 10
Cupronickel Exchanger
a) Re-install front access panel.
b) Place a garden hose into the pool side inlet of the heat
pump; wrap a clean rag around the hose to form a
temporary seal.
c) Turn on the garden hose water supply.
d) Allow water to run through the heat exchanger for 2-3
minutes; fresh water should be seen exiting the pool's out-
port.
e) Place a garden hose into the source-side inlet of the heat
pump; wrap a clean rag around the hose to form a
temporary seal.
f) Turn on the garden hose water supply.
g) Allow water to run through the heat exchanger for 2-3 minutes; fresh water should be seen
exiting the out-port connection unions.
h) After flushing is complete, shut off and remove the water supply.
i)
Place an air hose into the pool inlet of the heat pump; wrap a clean rag around the hose to
form a temporary seal.
j)
Push all water from the water circuit using compressed air at approximately 50 psig. The
residual water should be forced out of the pool out connection.
k) Allow compressed air to blow into the heat pump inlet connection unions for at least 15-20
seconds after water stops coming out of the pool outlet.
l)
Repeat process on source side.
m) Partially reconnect plumbing connection unions.

3.3 Planned Maintenance

An annual inspection and maintenance program is strongly recommended starting one (1) year after
installation of heat pump. See Figure 6 for recommended inspection checklist. AquaCal AutoPilot can
perform this service in limited areas. Contact Customer Support for more information.
WARNING
- Failure to heed the following may result in injury or death.
Check Water Flow
Clean Evaporator Coil
Check Relay Contacts
Check Capacitor Values
Check Refrigerant Levels
Clean Heat Pump Cabinet
Check Flow/Pressure Switch
Check Electrical Connections
Check Proper Voltage To Unit
Annual inspection and service must be performed by a qualified pool and heat pump
specialist in order to prevent physical injury or damage to equipment.
Planned Maintenance Checklist
Check Pool & Spa Water Chemistry
Check and Clean Condensate Drains
Check Compressor Amperage Draw
Check Water Pump Amperage Draw
Acid Wash Source Coil (As Applicable)
Check Air Temperature Change Through Evaporator
Check Operating Controls and Temperature Sensors
Check Water Temperature Change Through Heat Exchanger
Cupronickel Exchanger
(no drain plug)
Figure 5
Figure 6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Autopilot ws05Autopilot ws10Autopilot sp05

Table of Contents