Programming - Westfalia 82 63 73 Instruction Manual

Sliding gate opener
Table of Contents

Advertisement

DIP Switches 1 – 2 for Adjusting the Midway Mode
Example:
Run Time of the Sliding Gate Opener in Midway Mode = 6 Seconds
(2 + 4 Seconds)
DIP Switches 3 – 5 Fine Adjustment of the Soft Stop Time
Example:
Soft Stop Time = 1.5 Seconds (0.5 + 1 Second)

Programming

DIP Switch 1: ON = 2 Seconds
DIP Switch 2: ON = 4 Seconds
Factory Default of both switches is OFF
= Midway Mode Function is disabled
DIP Switch 3: ON = 0.5 Seconds
DIP Switch 4: ON = 1 Second
DIP Switch 5: ON = 2 Seconds
Factory Default of the switches is OFF
= Soft Stop Function is disabled
14
OFF = 0 Second
OFF = 0 Second
OFF = 0 Second
OFF = 0 Second
OFF = 0 Second