4.2.5 Line Period Limits

Table 2 Line Period Limit Definition (LVDS Model)

Model
LD3521
LD3522
LD3523
LD3541
LD3542
LD3543
PerkinElmer™ ™ Optoelectronics
# Pixels
Clock
Max Line Scan
512
20 MHz
34,013 L/sec
1024
20 MHz
18,181 L/sec
2048
20 MHz
9,416 L/sec
512
40 MHz
68,027 L/sec
1024
40 MHz
36,363 L/sec
2048
40 MHz
18,832 L/Sec
10
Min. Line
Rate
Scan Period
29.4 µsec
55.0µsec
106.2 µsec
14.7 µsec
27.5 µsec
53.1 µsec