Engineered System Manual
5.0 BU-2H06D-7588 Base Unit Details
5.1 BU-2H06D-7588 Hardware Configuration
Table 4. BU-2H06D-7588 Base Unit Hardware Configuration Details
Required Fields
Control Power
Number of I/O Channels
Output Composition
Antenna Option
Frequency
Note: Input channels are active when the input is switched-to-ground (same potential
as P1:12). For the input to be considered active, the voltage at the input channel must
be less than 1V relative to P1:12 for at least 100msec. For the input to be considered
inactive, the voltage at the input channel must be greater than 3V for the same
minimum amount of time. All input channels are equipped with internal pull-up
resistors. Therefore, when an input is disconnected from an input channel, the input is
considered inactive.
5.2 BU-2H06D-7588 Safety Link
SAFETY LINK ENABLED – In the event that the handheld and base unit lose communication,
the base unit will deactivate any active outputs. In the event that communication is re-
established, no active commands can be present in the initial communication in order for a link
to be established and for outputs to be affected by the handheld and by proxy in this application
the other base units. Safety Link is based on a five (5) second window – in the event that no
message is received from the handheld within five (5) seconds after receipt of the last valid
message, any active outputs will be disabled.
5.3 BU-2H06D-7588 Channel Configuration Details
Table 5. BU-2H06D-7588 Base Unit Channel Configuration Details
Channel #
M1
Transmitter Low Bat
(Red LED)
M2
OK to Reset
(Amber LED)
M3
OK to Drill (Green LED)
M4 (Not used)
M5 (Not used)
M6
Reset Input
2013 Cervis, Inc.
Interface Description
12VDC
6
FET
EXTERNAL
2.4GHz
Type
Style
Level
Momentary
Output
Level
Latched ON
Output
Latched OFF
Level
Latched ON
Output
Latched OFF
Level
Level
Level
Momentary
Input
Custom Code Notes
Low Battery signal sent from HH
(active for 30 seconds)
B1
B2 OR Loss of link
M2 AND M6 ACTIVE
HH OFF OR Loss of link
Switch to ground input from reset switch
Active when<1, not active when >3
7