Device
Fig. 7:
Connecting wires
Fig. 8:
Mounting the support ring
Abb. 9:
Attaching the device
Product manual 2CKA001473B9085
Connection and installation
Note that the connecting cables for the
power supply, the free@home bus and
the external RTC temperature sensor
(option) must be fed through the
previously pierced cable feed-through on
the left side. Also a cable duct (Ø 20 mm)
can be used as an option.
1. Connect the free@home bus line and
power cord of the 24 V power supply
with the terminal block.
Observe the correct polarity!
Circuit diagrams: see chapter 5.3
"Circuit diagrams" on page 14.
2. Insert the support ring into the flush-
mounted installation box.
A fine adjustment can be carried
out via the two elongated holes.
3. Screw the support ring to the flush-
mounted installation box via the
elongated holes.
The two other holes *) can be
used for screwing to the wall
(optional!). Here the
corresponding option for fixing to
the wall is to be observed.
4. Attach the device to the support ring.
The device is held magnetically!
Observe the correct position of the multi-
point connector.