Main menu options
Option 5 — Digital boards
This option allows you to set up the clock source (outputs), SRC and word size for any
digital I/O board(s) fitted in the unit. This option has eight boards to choose from —
"A" to "H" (printed on the rear panel) — each one representing a module slot position.
Clock source and word size are for digital outputs only, whereas SRC is for inputs and
outputs. The channels are configured in pairs.
If there are no digital I/O boards fitted, this option does not appear. However, if one or
more digital I/O boards are fitted, all of the board positions (A to H) appear in the
menu.
>> To select the digital I/O board (module position)
1
Enter the main menu, as described in "To enter the main menu" on page 16.
2
Use the up/down arrow buttons to go to option 5 (digital boards).
Note: This option does not appear if there are no digital I/O boards fitted.
3
Press SELECT to display the screen for module position (board) A.
4
Use the up/down arrow buttons to go to the board you require.
>> To set up the clock source for a pair of digital outputs
1
After selecting the digital I/O board you wish to configure (see "To select the
digital I/O board (module position)" on page 19), press SELECT to go to the
"Clock Setup(out)" screen.
Note: Pressing SELECT has no effect if there is no digital I/O board fitted in this
position. Also, pressing MENU takes you to the option 5 display, whether a digital I/O
board is fitted or not.
2
Press SELECT to go to the "Select Channels" screen.
3
Use the up/down arrow buttons to go to the pair of channels you wish to
configure (1 and 2, 3 and 4, 5 and 6 or 7 and 8).
4
Press SELECT to go to the "Clock source" screen.
5
Use the up/down arrow buttons to select the clock source from the following
options:
• "48K" — 48k clock source.
• "96K" — 96k clock source.
6
Press SELECT. The display will briefly display the "Saving new setting" screen
and revert to the "Clock source" screen.
7
Press MENU as many times as necessary to do one of the following:
• Exit this option.
DL351 Modular I/O
Operator Manual
"From Inputs" — the digital inputs are used as the clock source.
Configure another pair of channels.
19