Dimensions; Minimum Clearance To Combustibles - Napoleon Oakville Series Installation Manual

Hide thumbs Also See for Oakville Series:
Table of Contents

Advertisement

Available languages

Available languages

1.5

dimensions

1.6

minimum clearance to combustibles

This appliance must be recessed into a vented non-combustible wood-burning appliance (prefabricated or
masonry) only. The minimum appliance opening size in which the appliance is to be installed is:
HEIGHT 24 3/4" (62.8cm)
The minimum allowable chimney flue size is 6" (152mm) round.
The minimum distance, from the bottom of a combustible mantel projecting 3" (76mm) maximum from the wall to
the top of the appliance, is 12" (30.5cm) (see "minimum mantel clearances" section).
note:
A non-combustible hearth must protrude a minimum of 12" (30.5cm) from the appliance.
note:
A combustible hearth may be used if the appliance is raised 4" (102mm) above the hearth or if a Wolf Steel
raiser box is installed.
front view
SAFETY
BARRIER
top view
3"
[76mm]
2 PLS
1
34
8 "
[867mm]
WIDTH 34 5/16" (87.1cm)
general information
11
24 9
23
16 "
"
16
[601mm]
1
624mm
16
2 "
[419mm]
3
17
4 "
[450mm]
DEPTH 18 1/4" (46.3cm)
side view
1
8
16 "
[204mm]
W415-1799 / B / 06.11.19
EN