Drive The Digital Output; Query Status Of The Digital Input - Vivotek IP7138 User Manual

Vivotek user's manual network camera ip7138
Hide thumbs Also See for IP7138:
Table of Contents

Advertisement

Drive the digital output

Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>]
[&do3=<state>][&do4=<state>][&return=<return page>]
Where state is 0, 1. "0" means inactive or normal state while "1" means active or
triggered state.
PARAMETER
VALUE
0, 1
do<num>
<return page>
return
Example: Drive the digital output 1 to triggered state and redirect to an empty page
http://myserver/cgi-bin/dido/setdo.cgi?do1=1

Query status of the digital input

Note: This request requires the privilege of viewer.
Method: GET/POST
Syntax:
DESCRIPTION
0 – inactive, normal state
1 – active, triggered state
Redirect to the page <return page> after the
parameter is assigned. The <return page> can be
a full URL path or relative path according the the
current path. If you omit this parameter, it will
redirect to an empty page.
- 87 -
www.vivotek.com

Advertisement

Table of Contents
loading

Table of Contents