DT9100 B
Use supervisor
Code
Use supervisor
code
Use supervisor
code
Use supervisor
code
20180905-V1
Setting the synchronisation time (Synchron Time)
Here you can preset the synchronisation time for a remote
synchronising function.
(The seconds are set to zero automatically.)
Setting the synchronisation pulse width (Synchron Gate
Time Set)
Here you can set the pulse width of a remote
synchronisation signal. When the active state of the
synchronising pulse is lower then this value, the instrument
doesn't accept it as a synchronisation pulse.
E.g. when
terminals 7 and 8 closed for more than 2 seconds before
opening it to activate the synchronisation.
1. digital output mode (Output 1)
Here you can set Out1 (terminal 1 and 2) digital output
mode.
You can use it for synchronising other clocks by selecting
the repeater function.
2. digital output mode (Output 2)
Here you can set Out2 (terminal 3 and 4) digital output
mode.
You can use it for synchronising other clocks by selecting
the repeater function.
is selected, then you should keep
51