Make sure that the amount of mains power available
from the input supply is adequate for normal operation of
the machine. The necessary delayed fuse (or circuit
breaker with "D" characteristic) and cable sizes are
indicated in the technical specification section of this
manual.
Output Connections
Refer to points [6], [7] and [8] in the Figure 4.
Controls and Operational Features
POWERTEC 205C
2
5
1
4
3
6
7
8
Figure 4.
1. Power Switch ON/OFF (I/O): Controls the input
power to the machine. Be sure the power source is
connected to the mains supply before turning power
on ("I"). After input power is connected and the
power switch is turned on, the power switch will light
up to indicate the machine is ready to weld.
2. Thermal Overload Indicator: This lamp
will light up when the machine is
overheated and the output has been
turned off. This can occur if the ambient
temperature is above 40°C or the duty cycle of the
machine has been exceeded. Leave the machine on
to allow the internal components to cool, when the
lamp turns off normal operation is possible.
3. Welding Load Voltage Switch: Adjust the
welding load voltage. POWERTEC 205C
has 1 switch (10 steps). POWERTEC
255C and 305C have 2 switches (2 and 10 steps).
WARNING
Do not switch Welding Load Voltage [3] during welding.
4. WFS (Wire Feeding Speed) Control
Knob: It enables continuous control of
wire feeding speed in the range from 1 to
20 m/min.
5. Digital Display Panel: Available as an option(see
"Accessories" chapter).
6. EURO Socket: For connecting a welding gun (for
GMAW, FCAW-GS / FCAW-SS process).
English
POWERTEC
255C & 305C
2
5
1
4
3
6
7
8
7. Low Inductance Negative Output Socket:
For connecting a work lead.
8. High Inductance Negative Output
Socket: For connecting a work lead.
POWERTEC 205C
9. Gas Connector: Connection for gas line.
The welding machine supports all suitable shielding
gases at a maximum pressure of 5,0 Bar.
10. Hole Plug: For CO
"Accessories" chapter - K14009-1 CO
Connection Kit).
11. Power Lead (5m): Connect the supply plug to the
existing input cable that is rated for the machine as
indicated in this manual, and conforms to all
applicable standards. This connection shall be
performed only by a qualified person.
K14054-1 POWERTEC 205C 400V
K14054-2 POWERTEC 205C 230/400V
23
22
21
20
19
12
4
POWERTEC
255C & 305C
9
10
11
Figure 5.
WARNING
gas heater socket (see
2
Heater
2
17
24
16
14
15
Figure 6.
9
10
11
English