MAINTENANCE
GENERAL
Developing a good preventive maintenance (PM)
program is key to keeping any system operating
properly, the frequency of which is determined by
each individual installation. Contact your Ransburg
representative or the Ransburg Service depart-
ment for guidelines or assistance in establishing
a preventative maintenance program.
For maintenance of system components other
than the PulseTrack 2, refer to the appropriate
manual or contact your Ransburg repre-sentative
or Ransburg Customer Service.
SCHEDULED
MAINTENANCE
There is no maintenance schedule for the control
panel other than good housekeeping practices.
These include:
1. Keeping the door closed at all times to maintain
the dust-tight environment that is preferable for
the electronic circuit boards and wiring.
2. Plug all unused access holes in the cabinet to
keep contaminants out.
3. The cabinet exterior may be cleaned with a
clean, dry, lint-free cloth. If necessary, isopropyl
alcohol or other mild cleaning solutions can be
used.
4. Window cleaner or a mild solvent may be used
to clean the glass window in the small swing-out
door.
REPLACEMENT
PROCEDURES
W A R N I N G
!
Field repair and troubleshooting of the
>
PulseTrack 2 Control Panel may require
exposure to potentials that can cause
SERIOUS BODILY INJURY or DEATH if
proper procedures are not followed. For
this reason, troubleshooting and field repair
should only be accomplished with specif-
ic test equipment by qualified electronics
technicians or authorized Ransburg repre-
sentatives.
Fuses (F1, F2 - reference
Figure 4)
1. Turn off AC Power to the control panel at the
Fused Disconnect.
2. Open the cabinet door and locate TB3 in the
upper left corner of the cabinet.
3. Pull up on the center portion of terminal block
TB3-F1 or TB3-F2 to access the fuse.
4. Push the fuse out with a small screwdriver or
similar tool and replace with a new one.
5. Push center portion of terminal block back in,
secure cabinet door and restore AC power.
Atomizer or Temperature/
Humidity Card
1. Turn off AC Power to the control panel at the
Fused Disconnect.
2. Open the cabinet door and disconnect the rib-
bon cable from the rear of the card to be replaced.