Optional Temperature/ Humidity Card Controls - Ransburg Pulsetrack 2 Service Manual

Speed control and monitor system
Table of Contents

Advertisement

Local/Remote Switch
When the local/remote switch is in the local posi-
tion, the setting on the Speed Select Thumbwheel
switch is used to determine the speed output (see
"Local Mode Operation" in the "Operation" section).
When this switch is in the remote position, the
analog speed setpoint inputs are used to determine
the speed output (see "Remote Mode Operation"
in the "Operation" section).
Speed Enter Button
This button is used in local mode to confirm speed
setting changes made using the thumbwheel
switch (see "Speed Select Thumbwheel Switch "
in the "Operation" section).
Enable/Disable/Reset Switch
This switch must be in the enable position to enable
speed control for a given rotator. If this switch is in
the disable position, speed control for that rotator
is disabled. Faults may also be reset by moving
this switch to the disable position.
Active Indicator
This green LED illuminates when speed control
is enabled on a given rotator.
Figure 13: Atomizer Card Operating Controls
OPTIONAL
TEMPERATURE/
HUMIDITY CARD
CONTROLS
(See Figure 14)
Temperature/Humidity Display
This three digit display indicates temperature from
32 to 199°F (0 to 100°C) or relative humidity from
0 to 100%.
Temperature/Humidity Switch
This switch selects whether temperature or rel-
ative humidity is displayed on the temperature/
humidity display.
°F/°C Switch
This switch selects whether the temperature dis-
play is in Fahrenheit (°F) or Celsius (°C).
Active Indicator
This green LED illuminates when the Temperature/
Humidity Card is functioning properly.
Figure 14: Optional Temperature/Humidity
Card Controls