NOTE
>The AC power must be cycled for the
new dip switch setting to be recognized.
TABLE 7 - ATOMIZER CARD SW2 DIP SWITCH SETTINGS
Ordering
Configuration
A11515-XXX1X
6" Conical Disk
A11515-XXX4X
6" UniDisk
A11515-XXX5X
8" UniDisk & 9" Conical Disk
A11515-XXX6X
10" UniDisk
A11515-XXX7X
12" UniDisk & 12" Conical Disk
A11515-XXX2X
Standard Aerobell
A11515-XXX8X
A11515-XXX3X
Aerobell 33 (30 & 57mm)
A11515-XXX9X
Temperature/Humidity Card
There is also a 4 position dip switch SW2 located
near the bottom of each temperature/humidity
card. These dip switches should always be set
to the OFF position.
Rotary DIP Switch
There is a rotary DIP switch SW1 located on each
Atomizer and Temperature/Humidity Card (see
Figure 11). The setting of this switch must match
the slot number the card is occupying as listed on
the label inside the front panel door (reference
Figure 18).
Rotator Type
SW2-2
SW-2-1
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
Figure 11: Atomizer Card Dip Switch
Maximum
SW2-4
SW2-3
OFF
OFF
40,000 rpm
OFF
OFF
27,000 rpm
OFF
ON
23,000 rpm
ON
OFF
15,000 rpm
OFF
OFF
15,000 rpm
ON
ON
60,000 rpm
OFF
ON
50,000 rpm
Speed